Patriot Remote Test Station Monitor by OmniMetrix

Employs a Two-Coupon System in Conjunction with a Permanent Reference Electrode

Description

The TrueShield™ Patriot™ Test Station Monitor is designed as a self-contained wireless remote monitoring unit for test stations. To ensure compliance with the Code of Federal Regulations (CFR) 49, Parts 192 and 195, which requires regular measurements of the corrosion protection (CP) system, the Patriot employs a two-coupon system in conjunction with a permanent reference electrode (Copper-Copper Sulfate) to take these measurements and transmits them wirelessly to OmniView®, our secure, web-based data management center.

Benefits

  • CP System Extends Pipeline Lifetime
  • Reduces Inspection Costs
  • Leverages Extensive Cellular or Satellite Coverage
  • Durable Polycarbonate Enclosure
  • Internet Delivered Alarms and Data
  • Accurate Data Retention


OmniUpdate

OmniUpdate is OmniMetrix patented technology that performs remote software updates. There is no need to purchase multiple versions of firmware or make periodic field visits to the monitor with a laptop. The Patriot’s firmware is automatically updated over the air so that all units are always running the latest version.

Why use a coupon system?

Coupons may be used in a wide variety of applications. The most common is for buried or submerged pipelines. They are also used for USTs, on-grade storage tank bottoms, reinforcing steel in concrete, internal surfaces of elevated or on-grade water storage tanks and various other structures in aqueous environments. Coupons may be used when any of the following conditions occur:

  • Current from multiple rectifiers must be interrupted synchronously or non-synchronously.
  • Foreign CP systems are present in the area, for which either the locations are unknown or the rectifiers cannot be interrupted, resulting in IR-Drop errors in the off-potential measurement.
  • Sacrificial anodes are directly connected and cannot be interrupted, resulting in IR-drop errors in the off-potential measurement.
  • Long-line or telluric currents that result in IR-drop errors that interruption cannot eliminate.
  • Stray current that causes significant IR-drop errors in the off-potential measurement.
  • Structures utilizing polarization or depolarization criterion.
  • Appendix D1, Criteria for Cathodic Protection CFR 49 Part 192 n Locally corrosive areas in an otherwise noncorrosive environment.
  • Rapid IR spikes immediately following interruption that cause errors in the off-potential measurement.
  • Multiple pipelines in the same right-of-way that produce interference with one another.
  • The structure may be under the influence of alternating current n No known CP problem exists, but additional information is desired.

Specifications

 Application   Certifications
 CP Measurements: 
  • Pipe-to-Soil
  • AC Measurement
  • Potential-to-Structure
  • IR Drop 
  • AC Current Density
  • EMC: FCC Part 15, Class B
  • Radio Compliance: FCC Parts 22 & 24 
  • Safety: UL 60950-1, IEC 60950-1
  • Rated Class 1, Div. 2, C&D
 Specifications  Features 
  • Sensors: Two Coupons (If Required)
  • Reference Electrode (Customer Provided)
  • Temp: -20 C to +70 C
  • Sealed Enclosure
  • ±10VDC Input
  • 10-Year Lithium Battery
    • (Based on one set of readings per day, reported weekly)
  • Easy to Install
  • OmniUpdate™ Remote Firmware Updating
  • Wireless to Web
  • OmniView®, Secure Website
    • Featuring ScopeView™
  • Remotely Programmable Measure and Report Interval
  • 10-Year Battery (Replacements available through OmniMetrix)
  • Programmable Depolarization Delay: 1-6 days
  • Signal Strength Display
  • No Custom Software
 Wireless Network   Benefits
  • 4G Cellular Digital Radio  (2G, 3G Compatible) 
  • Call about Satellite
  • CP System Improvement to Defer Pipe Reconstruction
  • Leverages Extensive Cellular Coverage
  • Durable Polycarbonate Enclosure
  • Internet Delivered Alarms and Data  
 Size  Inputs
  • 4” Diameter
  • Telescoping up to 99’’ Long (Transmission Model)
  • Partial Buried (24” Long Distribution Model)
  • Reference Electrode
  • Non-Protected Coupon
  •  Protected Coupon 
  • Structure