Eliminate corrosion problems at pipe supports with the Nu-Bolt™
and I-Rod® dielectric pipe support system by Deepwater.

The Problem

Corrosion at pipe supports is one of the leading causes of process piping failures. It is the beam supports and saddle clamps that have historically caused the majority of problems. These have the following undesirable features in common:

  • Crevices – the formation of a crevice at the pipe surface.
  • Water Entrapment – water is trapped and held in contact with the pipe surface.
  • Poor Inspectability and Maintainability – virtually impossible to paint or otherwise maintain; visual and/or NDT inspection are often difficult.
  • Galvanic Couples – even when both the pipe and support are steel, the metallurgical differences can still provide enough potential difference to drive a corrosion cell.

The Corrosion Mechanism:

  1. Water is trapped.
  2. The paint system fails (atmospheric coatings soften in immersion service).
  3. Corrosion is initiated.
  4. Corrosion undercuts paint film.
  5. Crevice corrosion starts.
  6. Pipe fails.

The Solution

Nu-Bolt™ and I-Rod® have been specified on thousands of offshore production platforms since 1987. They simply and economically address the root cause of crevice corrosion by:

  • Eliminating crevices.
  • Eliminating water entrapment.
  • Eliminating metal-to-metal contact.
  • Allowing for ease of inspection and maintenance.
  • Providing complete support to the piping system.
Nu-Bolt™

Designed by corrosion engineers, Nu-Bolt™ is a standard pipe U-Bolt modified with a variety of corrosion resistant treatments to provide reliable, long-term service in severe operating environments associated with offshore oil & gas production and coastal process facilities.

Type 316 alloy stainless steel is used as the structural metal. This is a molybdenum-bearing grade steel which gives the better overall corrosion resistance properties than Type 304 and higher creep strength at elevated temperatures. Type 316 resists chloride attack, and is ideal for use in marine atmospheres and other corrosive environments.

Polyshrink is applied over the shank of the U-Bolt to protect the paint system during installation. Polyshrink is not designed to protect the U-Bolt. The material is a crosslinked, high compressive strength, UV-stable polyolefin, and is good for continuous operation up to 230°F (110°C).

Standard, stocked U-Bolt coatings:

  • Hot Dip Galvanize – suitable for moderately aggressive areas.
  • SermaGard® – an aluminum-ceramic coating offering superior corrosion resistance in aggressive environments.

I-Rod®

I-Rod® is a high-strength thermoplastic rod in a half round configuration. I-Rod is inserted so the round surface interfaces with the pipe.

The half round profile:

  • Minimizes contact crevice, and thus eliminates moisture retention.
  • Provides a standoff between the pipe and support, and thus:
    - Insulates electrically.
    - Improves maintainability.
    - Improves inspectability.

The high-strength thermoplastic material also:

  • Provides excellent compressive strength.
  • Is UV stable.
  • Has a low friction coefficient, which assists in pipe fitting when used as a beam dressing, and reduces coating damage during new construction.

When used independently as a beam dressing, I-Rod® is typically supplied in 5’ and 10’ lengths.

Specifications

I-Rod Specifications (Standard High Impact Thermoplastic)
 

Property Value Units ASTM Test Value

Density, 73ºF

-

D792

1.41

Tensile Strength, 73ºF

psi

D638

9,800

Tensile Modulus of Elasticity, 73ºF

psi

D638

440,000

Elongation (at break), 73ºF

%

D638

30-60

Flexural Modulus of Elasticity, 73ºF

psi

D790

455,000

Flexural Strength, 73ºF

psi

D790

13,800

Compressive Strength, 10% def, 73ºF

psi

D695

16,000

Coefficient of Friction (dry vs steel) Dynamic

-

PTM 55007

0.25

IZOD Impact (notched), 73ºF

ft-lbs/in of notch

D256

1.5

Hardness, Rockwell, 73ºF

-

D785

119-122

Deformation Under Load

%

D621

1.0

Melting Point

ºF

D3418

329

Coefficient of Linear Expansion

in/in/ºF

E831

5.8 x 10-5

Continuous Service Temperature

ºF

-

194

Heat Deflection Temperature, 264 psi

ºF

D648

220

Flammability Rating

-

VL94

HB

Volume Resistivity

Ohm-cm

D257

1.0 x 1015

Dielectric Strength, Short Term

V/mm

D149

420


I-Rod HT Specifications (High-Temperature Applications)

 
Property Value Units ASTM Test Value

Density, 73ºF

-

D792

1.28

Tensile Strength, 73ºF

psi

D638

16,500

Tensile Modulus of Elasticity, 73ºF

psi

D638

475,000

Elongation (at break), 73ºF

%

D638

80

Flexural Modulus of Elasticity, 73ºF

psi

D790

500,000

Flexural Strength, 73ºF

psi

D790

20,000

Compressive Modulus, 73ºF

psi

D695

480,000

Compressive Strength, 10% def, 73ºF

psi

D695

22,000

Coefficient of Friction (dry vs steel) Dynamic

-

PTM 55007

0.42

IZOD Impact (notched), 73ºF

ft-lbs/in of notch

D256

0.5

Hardness, 73ºF

-

D785

R125 / M112

Melting Point

ºF

D3418

N/A

Coefficient of Linear Expansion

in/in/ºF

E831

3.1 x 10-5

Continuous Service Temperature

ºF

-

340

Heat Deflection Temperature, 264 psi

ºF

D648

392

Flammability Rating

-

UL94

V-O

Volume Resistivity

Ohm-cm

D257

6.7 x 1017

Dielectric Strength, Short Term

V/mm

D149

830

Thermal Conductivity

BTU-in/ ft2 hr ºF

C177

0.90

Flammability Rating

 

UL94

V-O

Nu-Bolt Pipe Bolt Dimensions

Questions & Answers

To assist our customers, we have put together answers to the most frequently asked questions regarding I-Rod pipe support systems.

Q:   “Is I-ROD made of Teflon?”
A: No, I-Rod is a high-impact thermoplastic material. Teflon would not function due to lack of compressive strength.
Q: “Is the material on a Nu-Bolt Neoprene?”
A: No, it is a cross-linked, heat-shrinkable polyolefin material. Neoprene would have to be vulcanized to stick to the U-Bolt, and would deform too much, and cause problems with moisture.
Q: “What is the maximum piping temperature that I can use I-Rod on?”
A: Normally, at temperatures above 90°C (194°F) crevice corrosion is not a problem, because the water simply evaporates. This is therefore our upper recommended continuous service temperature. The material will, however, perform up to 120°C (250°F), but may experience some slight deformation at the contact area.
Q: “Does the I-Rod create a stress raising point on the pipe?”
A: No, not if the piping is correctly supported along it’s length. If there is noticeable sagging between support points then the pipe is being overstressed, and inadequately supported. Note: I-Rod has been used on hundreds of thousands of pipe supports since 1987 years, and we have never seen a problem.
Q: “How do I know I’m buying I-Rod and not some inferior copy?”
A: Every shipment of I-Rod is traceable, and is sent with a certificate of authenticity. I-Rod is distinctly marked as such.

A Case Study of 13 Years of Offshore Exposure

The photos below were recorded during a routine topside inspection of an offshore structure that was installed in 1989. This was the first offshore structure where the I-Rod system was specified for new construction. The total added cost of this system was less than $10,000. The photos demonstrate the success of the system, which has subsequently been used on thousands of offshore structures.

Installed Nu Bolts - No crevice corrosion. Fuel gas line, always wet. Green coloration is mold. The beam paint system has failed, but there is not corrosion at pipe support.
I-Rod installed under pig launch/receive barrel, bolted to support beams. I-Rod was found particularly effective on small diameter, screwed piping, which typically has the highest maintenance cost per square foot.
 
I-Rod were also found effective on the largest diameter piping of the offshore structure.  

 

Corrosion Control Products Company

  

Corrosion Control Products Resources

 Search this Website
 Request Quote
 Order Products Online
 Industry Links
 CCP Suppliers
 Installation Guides
 MSDS
  

Cathodic Protection Products & Materials

  

Home

Products Search Request Quote Order Online

Corrosion Control Products Company
800-421-2623

Tel: 

 310-532-9314
Fax:  310-532-1472

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.ccpco.com

© 1996-2011Corrosion Control Products Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956