Navigation:
CCP Home > Products
> Epoxy Coatings >
Canusa
CANUSA
HBE-95-BG
Brush-Applied, High-Build
Epoxy Coating

High-build
epoxy coating for buried pipelines, operating up to 95°C (203°F).


Product
Description
HBE-95 is a "state of the art"
surface coating designed to solve specific industry problems by
combining the unique features of epoxy and proprietary cure
technologies.
HBE-95 is a 100% solids,
two-component epoxy coating system which has been specifically designed
as an exterior coating applied to bare steel for protection of pipe
joint girth welds, valves and fittings, or as a touch-up material or
rehabilitation system for mainline coatings.
Typical
Uses
Protective coating for pipelines in
buried or immersed applications. Used as a direct-to-metal corrosion and
abrasion-resistant coating and as a rehab coating on steel pipelines and
at girth welds. Also used as touch-up material for mainline coatings.
Excellent coating for pipeline valves, fittings, and bends.
Features
- High Build in a single coat.
- Sets and cures over a broad temperature
range
- Environmentally safe.
- 100% solids, Zero V.O.C.
- Excellent adhesion to grit blasted steel
-- an ideal mainline corrosion coating for pipelines.
- Superior adhesion to Fusion Bonded Epoxy
(FBE) Coatings -- ideal coating for joint protection and repair of FBE
coated pipe.
- Excellent chemical & abrasion
resistance.
- Outstanding resistance to cathodic
disbonding up to 95°C (203°F) operating temperature.
- Easily applied with brush or roller.
About CANUSA-CPS
CANUSA-CPS-CPS is a leading manufacturer of specialty pipeline coatings
which, for over 30 years, have been used for sealing and corrosion
protection of pipeline joints and other substrates. CANUSA-CPS high
performance products are manufactured to the highest quality standards and
are available in a number of configurations to accommodate your specific
project applications.
|

|
Coating Description |
Epoxy |
|
Conversion to
Solids |
100% |
|
Theoretical
Coverage |
425 mil-sq. ft. / liter (1605 mil-sq. ft. / US gallon)
(1.0 mm-m2 / liter) |
|
Typical Thickness |
>20 mils |
|
Flashpoint
(T.C.C) |
>95°C (203°F) |
|
Mixing Ratio (by Volume) |
3 Parts Base to 1 Part Hardener |

Typical Product
Properties
|
Coating
Property |
Test
Standard |
Unit |
Typical
Values |
|
Hardness |
ASTM
D2240 |
Shore D |
>
85 |
|
Adhesion
To Steel (Sp10 at 24 mils)
To FBE |
ASTM D4541
ASTM D4541 |
psi
psi |
> 2000
> 2000 |
|
Cathodic Disbondment
28 days @ 23°C
28 days @ 80°C
28 days @ 95°C |
CSA Z245.20
CSA Z245.20
CSA Z245.20 |
mm, radius
mm, radius
mm, radius |
< 3
< 8
< 8 |
|
Impact
Resistance
at -30°C
at 25°C |
CSA Z245.20
CSA Z245.20 |
Joules (in-lb)
Joules (in-lb) |
> 3.0 (> 26.5)
> 3.0 (> 26.5) |
|
Hot
Water Immersion
28 days at 75°C
28 days at 95°C |
CSA Z245.20
CSA Z245.20 |
1 to 5
1 to 5 |
1, excellent
1, excellent |
|
Flexibility |
ASTM D570 |
deg / pipe diam. |
> 0.7 |
|
Water Absorption |
ASTM D149 |
% |
< 0.1 |
|
Dielectric Strength |
ASTM D543 |
Volts / micron
(Volts / mil) |
> 16
(> 400) |
|
Chemical Resistance |
ASTM
D543 |
various
solutions |
excellent |

Surface Preparation
- Direct-to-steel
Remove all visible deposits of oil, grease and other contaminates by solvent washing in
accordance with SSPC-SP1. Abrasive blast surfaces to a Near-White (SSPC-SP
10, NACE 2, SA2 1/2) or better,
with a 2-4 mil blast profile.
- On cured pipe coating
Remove gloss on surface by light
abrasive blasting or power tool. All surfaces to be coated must be
completely dry, free of moisture, soil, dust and grit at the time the
coating is applied. All weld splatter must be removed from the surface
and rough welds must be ground smooth prior to coating.
Cleanup, Storage
& Safety
- Clean-up
For clean-up use xylene, MEK or mixture.
- Storage
Products must be shipped and stored at temperatures between 15°C
(60°F) and 40°C (105°F). DO NOT FREEZE.
- Safety
Material Safety Data Sheet and product labels contain detailed
health, hygiene and safety information. This coating is intended for
industrial use by properly trained professional applicators.
Do not apply without adequate air exchange and ventilation in enclosed
areas. Use fresh air respirator in confined areas. Wear protective
clothing when spraying the coating. Breathing fumes or contact with
skin can cause respiratory and other allergic reactions in some
people. See MSDS for
HBE-95-BG Base and MSDS
for HBE-95-BG Cure.
Mixing &
Application Instructions
- For detailed application instructions
please refer to HBE-95 Installation Guide.
- Materials must be allowed to warm to at
least 28°C (70°F) prior to mixing.
- Pre-mix Base (more viscous component)
slowly with a variable speed drill gun fitted with an appropriate mixing
impeller.
- Pour pre-measured Hardener into
pre-measured Base.
- At temperatures between 15°C (59°F) and
40°C (105°F). Mix for one (1) minute blend both parts to create one
uniform color with no streaks. Begin mixing slowly. Caution: Mix at a
speed that ensures a uniform mix, but does not create a vortex in the
liquid. Slow mixer down at surface of the liquid to prevent introduction
of air into the coating.
- Pot-life is approximately 15 minutes at
20°C (70°F) and shortens with increased temperatures.
- HBE-95 must be applied to clean dry
surface only.
- Ambient conditions for successful
application include: relative humidity less than 85%; and the substrate
temperature greater than 3°C (5°F) above the dew point.
- The acceptable substrate temperature
range for application of HBE-95 is 10°C (50°F) to 100°C (212°F).
Applying onto warm substrate greater than 38°C (100°F) enhances coating
adhesion.
- Formulated to mixing ratio of 3 parts
Base to 1 part Hardener by volume.
- If additional coats are required, they
shall be applied while the preceding coat is still tacky (no tie coat
needed). The maximum over-coating interval shall not exceed two (2)
hours at 25°C (77°F) without roughening the surface. If recoating
interval has been exceeded, surface must be blast roughened prior to
application of topcoat.
- A minimum of four (4) hours curing above
20°C (68°F) is required prior to handling. Handling time maybe longer at
lower temperatures.
- Apply thoroughly mixed HBE-95 by brush,
roller or trowel. When coating pipe, remove application tools on the
upstroke to prevent pulling material down and off the pipe bottom.
|

|
Product Designation |
Package Contents |
|
HBE-95-BG
Kit-0.5
HBE-95-BG Kit-1.0
HBE-95-BG Kit-1.5
HBE-95-BG Application Kit |
375 mL of HBE-95
Base, 125 mL of HBE-95-BG Hardener.
750 mL of HBE-95 Base, 250 mL of HBE-95-BG Hardener.
1125 mL of HBE-95 Base, 375 mL of HBE-95-BG Hardener.
1 pair of rubber gloves, mixing sticks, application scraper. |

|