Home Products Contact Us Search Request Quote Order Online
 

    
Dielectric Nylon Pipe Bushings
by Illinois Plastics, Inc.


IVP Nylon Bushings insulate connections in water systems between
piping of different metals to prevent electrolysis & galvanic corrosion.

IVP manufactures a complete line of nylon pipe bushings in all thread sizes from 3/8 x 1/4 inch NPT to 2-1/2 x 2 inch NPT. The bushings are made with a heavy hex for wrenching.

IVP’s nylon pipe bushings are designed specifically to insulate connections in water systems between piping of different metals, such as iron or galvanized connected to copper or to high-copper content brass.

Preventing Electrolysis & Galvanic Corrosion

Why use insulating bushings?

Even a low mineral-content water performs as an electrolyte would in a battery. No current will be produced if two pieces of the same metal were immersed in an electrolyte and connected together, but if two different metals are used, a current will flow in a circuit through the electrolyte and any metallic connection outside the electrolyte (water). The dielectric bushing interrupts the metallic circuit and the electric current.

If the electric circuit is complete, as in metal-to-metal contact of the different pipes, the current through the water-electrolyte produces ions at the water-to-metal interfaces that are destructive of one or both metals. In the connection of copper to iron or galvanized, destruction or corrosion of the iron occurs with a heavy buildup of rust (iron-oxide) inside the pipe. The pipe wall may become corroded entirely through, and the inside passage will become severely restricted.

If the outside of the copper-iron pipe connection becomes wet due to condensation, or if the joint is immersed in water, corrosion of the iron will also occur on the outside.

The mineral content and acidity of the water supply affect the rate of corrosion, and both the mineral and acidity vary in domestic water supplies. Hot water is much more active than cold water, and many times a hot water pipe may be choked to a trickle of water, yet the cold water pipe next to it may be only moderately corroded.

The corrosion typically occurs in pipes within only 3 or 4 inches of the joint in pipes of ¾ size or smaller. If copper tubing is connected directly to a galvanized hot water tank, the entire inside of the tank is likely to corrode, with the zinc galvanizing disappearing first, then corrosion proceeding into the iron. Many such progressions have been observed. Any pinholes or bare spots in a “glass-lined” tank will corrode rapidly if copper tubing is connected directly to the tank.

Since the current developed in this corrosion process has a potential of only about 1¼ volts, any insulating interruption of the circuit will stop this corrosion. Nylon in a tough material and in the formulation used in IVP Bushings is resistant to water and the minerals formed in domestic water supplies with intermittent use up to 180ºF. If your application approaches 180ºF. we recommend individual testing of the bushing for your application.

As the water temperature is increased above 180ºF, long-term deterioration occurs, with higher temperatures accelerating the deterioration. Even a few months of exposure to 250ºF. water will seriously deteriorate the nylon.

Special Applications

Electrical ground connections for telephone and house wiring systems are commonly made by straps or clamps to water pipes. The electrical codes specify that these connections be made between the water service entrance and the first shutoff valve in the building. Since the code specification is sometimes disregarded and grounding connections are made to some other point in the plumbing system, installation of dielectric bushings may interrupt the electrical ground. A quick check should be made of the electrical ground connections whenever a portion of a pipe system is insulated with dielectric bushings.

Water softening and treating equipment produces greater chemical activity in the nearby systems. Even small differences in steel alloys used for tanks and piping can cause electrolytic corrosion in these areas. Protection with dielectric connections is desirable in all connections to the equipment.

Installation Instructions

All thread sizes (3/8 x ¼ to 2-1/2 x 2) of IVP Bushings are made with a heavy hex for wrenching. The nylon bushings are somewhat pliable and must be tightened securely. Also, the thread tapers are designed so that some flow of the nylon into inaccurate metal threads will occur if the thread size is within the specifications of the American Standards Institute.

The use of pipe dope for assembly is recommended even though the nylon will normally flow sufficiently to fill poorly cut threads in the metal. The dope lubricates during assembly as well as filling minor voids. None of the common paste or stick dopes have been found to affect the nylon. A stick dope that is wiped onto the threads should not be crumbly. Varnishes are sometimes used in production assemblies and are satisfactory if allowed to dry before use. Shellac should not be used in any case, since it is slightly soluble in cold water and will wash out completely in warm water.

Hemp or other fiber, or Teflon tape should not be used as a joint filler with nylon. The nylon will normally fill any properly sized threads if tightened securely as instructed above.

To obtain proper performance, the bushing is first screwed into the female fitting until the hex end is not more than one full thread from bottoming on the fitting: screw the hex all the way against the fitting if possible unless the fitting has a deep chamfer. If the bushing does not require a wrench for the last three threads at this stage, the thread in the fitting should be checked for oversize dimension.

The male pipe end or fitting should then be entered into the bushing and screwed in as tightly as possible with an appropriate wrench. Not more than one thread should be visible above the bushing hex, less if it can be screwed in farther. TIGHTEN THEM SOLID!

If the pipe end has been cut to an extra long thread, the small end of the thread should be either cut off if the female fitting has a shallow hole, or the small end should be screwed completely through the bushing until the large end of the tapered thread is close to or inside the hex of the bushing.

How to Avoid Joint Failures

Almost 100% of reported leaky joints have been due to failure to tighten the joints as far as it will go. Do not fail to tighten securely!

The balance of joint failures have been traced to improper threads in metal fittings or failure to allow relief for movement of the pipe system due to heating and cooling. If a section of a pipe system containing a nylon bushing is anchored securely at both ends and the pipe is heated and cooled, the resultant change in length is likely to distort or tear the nylon so that a leak can occur after one or more cycles of heating and cooling.

The remedy is to follow good mechanical practice and allow sufficient movement of one end or the other of the section that includes the nylon bushing, or to use the expansion bends to relieve the pressure. One case was found where a 1-1/2” pipe was connected to a heavy hot water boiler and run straight out for 12 feet, then at a right angle inside a brick wall. The calculated expansion of this pipe was over ¼” and the nylon bushing at the boiler end was simply torn apart.

 
    

Corrosion Control Products Company

 Epoxy Coatings
 Heat-Shrink Coatings
 Mastic Coatings
 Petrolatum Coatings
 Tape Coatings
 Surface Decontamination
 Moisture Seal Products
 Rockshields
 Inspection Instruments
 Insulated Fittings
 Insulators & Seals
 Flange Insulation
 Pipeline Cleaning Pigs
 Composite Systems
 Accessory Products

  

Farwest Corrosion Control Company

 Impressed Anodes
 Sacrificial Anodes
 Cable & Splicing
 DC Supplies & Rectifiers
 Remote Monitoring
 Polarization Cells
 Overvoltage Protection
 Junction & Bond Boxes
 Test Stations & Markers
 Reference Electrodes
 Test Instruments
 Insulating Materials
 Pipe Coatings & Tape
 Marine Products Division
 Offshore CP Systems
 Miscellaneous Products

  

More Corrosion Control Products Resources

 Search this Website
 Request Quote
 Order Products Online
 3-Ring Binder Catalog
 Industry Links
 CCP Suppliers

 MSDS
  

Home

Products Search Request Quote Order Online

Corrosion Control Products Company
800-421-2623

Tel: 

 310-532-9314
Fax:  310-532-1472

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.ccpco.com

© 1996-2008 Corrosion Control Products Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956