A Farwest Corrosion Control Company

Home Products Contact Us Request Quote Order Online

 
 

 Navigation: CCP Home > Products > Inspection Instruments > Non-Destructive Dry Film Thickness Gauges

Exchangeable Probes for FMP Series
Coating Thickness Gauges

by Fischer Technology

 

The quality of a coating thickness measurement depends on proper probe selection and the quality of the probe itself. Fischer Technoloy (Helmut Fischer GmbH) offers an unmatched variety of high-precision probes, all developed and manufactured in-house under the most stringent quality demands.

The coating/substrate material combination is decisive for selecting the appropriate probe. Important aspects for probe selection are the thicknesses of the coatin and the substrate material, the measurement area, and the shape and surface condition of the specimen.

A curvature-compensated probe (eddy current method) is available for specimens with different curvatures. Two-tip probes offer more accurate results on rough surfaces. Each instrument of the FMP10, FMP20, FMP30 and FMP40 family can be individually adapted to your requirements simply by changing the probe, and it is therefore suited for solving the most diverse measuring applications.

The diagram below shows criteria for selecting the appropriate probe. The probe assortment includes over 100 measurement probes for the most diverse areas of applications. Please contact Corrosion Control Products Company to discuss your coating thickness measurement application.
 

Magnetic Induction Measurement Probes
 

Design

Application

Range

Part No.

For electroplated coatings or paint and lacquer coatings.

0-2000 µm

FGAB1.3
604-141

Ideal for measurements in boreholes, pipes or grooves application diameter ≥ 9 mm.

0-1600 μm

FGABI1.3-150
604-175

For electroplated coatings, paint or lacquer coatings. Because of the large probe tip also suitable for rough surfaces.

0-1500 μm

FGA2H
604-174

Two-tip probe for greater repeatability precision on rough surfaces. Allows for reliable positioning and constant pressure force, even on soft coatings.

0-2000 μm

V7FKB4
604-180

Two-tip angle probe, particularly well suited for thick coatings. Greater repeatability precision on rough surfaces than single-tip probes.

0-8 mm

FKB10
604-177

 
Eddy Current Measurement Probes

 

Design

Application

Range

Part No.

Best suited for paint, lacquer or plastic coatings on non-ferromagnetic metal substrate materials.

0-1200 µm

FTA3.3H
604-142

Angle probe for measurements on flat specimens or in pipes, boreholes and interim spaces.

0-1200 μm

FAW3.3
604-1

Because of the excellent (patented) curvature compensation ideally suited for measurements on paint, lacquer, anodic and plastic coatings on curved NF surfaces.

0-800 μm

FTD3.3
604-189

 
Dual / Duplex Measurement Probes

 

Design

Application

Range

Part No.

For electroplated coatings or paint and lacquer coatings.

NF/Fe
0-1300 μm
Iso/NF
0-800 μm

FD10
604-143

Ideal for measurements in boreholes, pipes or grooves application diameter ≥ 9 mm.

0-800 μm

FDX10
604-246


 

Coating Inspection Instrumentation

 Cable & Metal Locators
 Dry Film Thickness
 Paint Inspection
 Wet Film Thickness
 Ultrasonic Thickness
 Holiday Detectors
 Surface Contamination
 Temperature & Humidity
 Surface Moisture
 Coating Adhesion
 Pit Depth Gauges
 Hardness & Inspection

 Coating Accessories

  

Corrosion Control Products Company

  

Corrosion Control Products Resources

 Search this Website
 Request Quote
 Order Products Online
 3-Ring Binder Catalog
 Industry Links
 CCP Suppliers
 Installation Guides
 MSDS
  

Farwest Cathodic
Protection Products
& Materials

  

Home

Products Search Request Quote Order Online

Corrosion Control Products Company
800-421-2623

Tel: 

 310-532-9314
Fax:  310-532-1472

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.ccpco.com

© 1996-2009 Corrosion Control Products Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956