Anode Consumption

The consumption rate of High Silicon Chrome Cast Iron anodes has been found to be between 0.2 and 1.2 pounds per ampere-year. For anodes of the same chemistry and microstructure, variance in consumption is primarily due to the chemical and physical characteristics of the anode environment. The consumption rate does not appear to be significantly affected by current density (amperes per unit area of anode surface). The use of coke breeze around the anode in soil ground beds will tend to lower the consumption rate. A generally accepted design guideline for anodes buried in coke breeze is 0.7 pounds per amp-year.

Current Density Limitations

The maximum stable current density of discharge may be limited by the environment regardless of the anode type. In free flowing water or in very wet soil ground beds, there is very little restriction on current density. However, anodes buried in clay soils tend to suffer "electro osmotic drying", a phenomenon of magnitude directly proportional to current density. For any particular soil with electro osmotic characteristics there will tend to be a critical maximum current density at the anode soil (or coke breeze to soil) interface, above which progressive drying occurs, with corresponding increases in anode-soil resistance. Drying is usually reversible by increasing soil moisture and/or lowering current density.

As a guideline to minimization of electro osmotic drying in groundbeds installed in clay soils, use of the following design maxima has resulted in stability of 90 to 95 percent of beds in areas of high osmotic drying potential.

Average soil resistitivity along groundbed, Ohm-cm Maximum Amps per anode in a coke breeze column, 12" OD by 60" Equivalent current density on surface of coke breeze column, Milliamps/sq ft
Less than 1000 2.00 127 (see note)
1000 - 1500 1.75 111 (see note)
1500 - 2000 1.50 96
2000 - 3000 1.25 80
Over 3000 1.00 64

Note: For greater success, limit current density to less than 100 mA/sq ft for soils of less than 1500 ohm cm resistivity.

Nominal Discharge Current Guide
for Anotec Anodes

Anotec
Anode
Type
Nominal
Weight
Current at
0.75 - 1.0 A/sq ft
8.1 - 11 A/sq m
Nominal
Dia.
Nominal
Length
Nominal
Area
lbs (kg) Amps inch (mm) inch (mm) sq ft (m2)
STICK
SHA, EHA 44 (20) 2.0 - 2.6 2 (50) 60 (1520) 2.6 (.24)
EHM 60 (27) 2.0 -2.7 2 (50) 60 (1520) 2.7 (.25)
EHK 26 (12) 1.5 - 2.0 3 (50) 60 (1520) 2.0 (1.9)
EHR 110 (50) 3.0 - 4.0 3 (76) 60 (1520) 4.0 (.37)
TUBULAR
2284 50 (23) 3.2 - 3.8 2.2 (56) 84 (2130) 4.2 (.39)
2660 50 (23) 2.6 - 3.5 2.6 (66) 60 (1520) 3.5 (.33)
2684 70 (32) 3.7 - 5.0 2.6 (66) 84 (2130) 4.9 (.46)
3884 95 (43) 5.3 - 7.0 3.8 (97) 84 (2130) 7.0 (.65)
4884 L 122 (55) 6.6 - 8.8 4.8 (122) 84 (2130) 8.8 (.82)
4884 H 177 (80) 6.6 - 10 4.8 (122) 84 (2130) 8.8 (.82)
4884 X 230 (104) 6.6 - 10 4.8 (122) 84 (2130) 8.8 (.82)
6784 270 (122) 9.2 - 12 6.7 (170) 84 (2130) 12.3 (1.14)
   
  • Note: Maximum amperage based on maximum value in manufacturer publications, 15-year minimum life criterion (0.7 lb/amp-year of 0.31 kg/amp-year) at 80% utilization, or 1 amp/sq ft (10.8 amp/m2).
  • Warning: Reduce current density in clay beds with high osmotic drying potential. Refer to Anode Consumption and Current Density Limitations in this web page.
  • Reference: NACE Technical Committee Report "Impressed Current Anodes for Underground Systems" [T10A-10 latest].
      

Cathodic Protection Products & Materials

 Impressed Anodes
 Sacrificial Anodes
 Cable & Splicing
 DC Supplies & Rectifiers
 Remote Monitoring
 Polarization Cells
 Overvoltage Protection
 Junction & Bond Boxes
 Test Stations & Markers
 Reference Electrodes
 Test Instruments
 Insulating Materials
 Pipe Coatings & Tape
 Miscellaneous Products

  

Cathodic Protection Services

 Farwest Engineering
 Farwest Installation

  

Cathodic Protection of Offshore Structures

 Galvanic CP Systems
 Impressed CP Systems
 Attachment Systems
 Monitoring Equipment

  

Marine Products Division

 Marine ICCP Systems
 Galvanic CP Materials
 Marine Growth Protection
 Electrolytic De-Scaling
 Electro-Chlorination

  

Pipeline Protection Products Division

 Epoxy Coatings
 Heat-Shrink Coatings
 Mastic Coatings
 Petrolatum Coatings
 Tape Coatings
 Surface Decontamination
 Moisture Seal Products
 Rockshields
 Inspection Instruments
 Insulated Fittings
 Insulators & Seals
 Flange Insulation
 Pipeline Cleaning Pigs
 Composite Systems
 Accessory Products
  

More Farwest
Website Resources

 Search this Website
 Request Quote
 Order Products Online
 View PDF Catalog
 Industry Links
 Farwest Suppliers
 Industry News
 Employment
 

Home

Products Services Search Request Quote Order Online

Farwest Corrosion Control Company
888-532-7937   (888-5FARWEST)

Tel: 

 310-532-9524
Fax:  310-532-3934

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.farwestcorrosion.com

© 1996-2008 Farwest Corrosion Control Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956