Farwest Corrosion
Control Company
 

Home Products Services Contact Us Search Request Quote Order Online
 

    
Model AT Modular AST
Impressed Current Anode

from EDI


Cathodic protection for above-ground storage tank bottoms

edi02.jpg (20883 bytes)

Features

  • Design flexibility - modular design permits multitude of anode configurations.
  • Light weight - very easy to ship and handle.
  • Simple to install - no field splices or weldments.

Design Compatibility

The Model AT is an impressed current anode specially designed for cathodic protection of above-ground storage tanks. It consists of a copper cored titanium flat wire coated with platinum or mixed metal oxide and attached to a #14 AWG HMW/PE insulated bus wire. The wire pair is surrounded by a flexible plastic mesh. Individual anodes are 50 ft. long and are easily connected in the field to form a hermetically sealed joint. This allows the design engineer to choose a layout which is best suited to the tank and its local environment.

Each component used in the Model AT has been field-proven in similar demanding applications; and therefore, it can be reliably operated up to 10 mA/ft for more than 50 years. Spiral layouts offer the most redundancy as well as uniform current output over the entire tank bottom. Alternatively, individual concentric rings permit varying current outputs where local conditions necessitate it. For any design configuration, the installation is quick and easy due to its light weight and flexibility.

Perhaps the most significant feature of the Model AT is its unique connector system. Each anode is supplied with a pin connector on one end and a socket connector on the opposite end which can be mated either to another anode section to form a string or to a power feed cable. Cables with the specially developed "tee" connector allow intermediate current feeds on long strings. These connectors are designed for underwater cable connections and are being used successfully on other EDI products in turbulent aqueous solutions. All connectors are factory made and sealed which means that there are no splices or weldments required in the field.

Connector Specifications

  Pin & socket material*   Brass Alloy 360
  Connector body   Neoprene
  Current rating   15 Amps
  Insulation rating   750 Volts
  Minimum insulation thickness   0.040"
  Contact resistance   < 0.01 ohm
  Insulation resistance   > 200 megohm after wet mating
  Pressure rating   20 kpsi
  Rated number of wet matings   500
  Connector shroud material   CPVC

*The terms Pin and Socket refer to the brass connector, not the CPVC shroud.

Notes
  1. When connector halves are fully mated, points (A) will align.
  2. Current output not to exceed 10 mA/ft.
  3. Individual anodes may be interconnected to form strings of any desired length. Power feeds must be no more than 1,000 feet apart.
  4. Current should be fed into anode strings from both ends. Longer strings should have additional intermediate feeds.
  5. Assemble individual anodes into strings by pressing pin end fully into socket end. The joint can be made permanent by using any solvent cement suitable for use with CPVC.

Installation

Anodes can be interconnected to form either one continuous string or several discrete strings. Lead wires are to be connected to both ends of anode strings. The Tee End Lead Wire is used to provide intermediate feeds. Distance between power feeds must not exceed 1,000 feet on single wire anodes.

To ensure optimum anode performance, anode should be covered with calcined petroleum coke or fine sand. Make sure the material filters through the poly mesh and completely encapsulates the anode.
  

Cathodic Protection Products & Materials

 Impressed Anodes
 Sacrificial Anodes
 Cable & Splicing
 DC Supplies & Rectifiers
 Remote Monitoring
 Polarization Cells
 Overvoltage Protection
 Junction & Bond Boxes
 Test Stations & Markers
 Reference Electrodes
 Test Instruments
 Insulating Materials
 Pipe Coatings & Tape
 Miscellaneous Products

  

Cathodic Protection Services

 Farwest Engineering
 Farwest Installation

  

Cathodic Protection of Offshore Structures

 Galvanic CP Systems
 Impressed CP Systems
 Attachment Systems
 Monitoring Equipment

  

Marine Products Division

 Marine ICCP Systems
 Galvanic CP Materials
 Marine Growth Protection
 Electrolytic De-Scaling
 Electro-Chlorination

  

Pipeline Protection Products Division

 Epoxy Coatings
 Heat-Shrink Coatings
 Mastic Coatings
 Petrolatum Coatings
 Tape Coatings
 Surface Decontamination
 Moisture Seal Products
 Rockshields
 Inspection Instruments
 Insulated Fittings
 Insulators & Seals
 Flange Insulation
 Pipeline Cleaning Pigs
 Composite Systems
 Accessory Products
  

More Farwest
Website Resources

 Search this Website
 Request Quote
 Order Products Online
 View PDF Catalog
 Industry Links
 Farwest Suppliers
 Industry News
 Employment
 

Home

Products Services Search Request Quote Order Online

Farwest Corrosion Control Company
888-532-7937   (888-5FARWEST)

Tel: 

 310-532-9524
Fax:  310-532-3934

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.farwestcorrosion.com

© 1996-2008 Farwest Corrosion Control Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956