Over-Voltage Protector 2
by Dairyland Electrical
Industries

Over-voltage protection for Division 2 or
ordinary locations.
Solid-state switching components to conduct at
very low voltages.


OVP2
Overview
The Over-Voltage Protector design
has been established since 1999 as the premier explosion-proof
(Division 1) protection device for insulated joints and related
applications. DEI now offers a variation of the OVP design in a
molded housing, designated the OVP2, for Division 2 or ordinary
locations. The OVP2 offers the same conservative design and
features of the OVP, but in a lighter weight and lower cost
package.
The OVP2 is UL and C-UL listed
for use in Division 2 or ordinary locations, as well as CE
marked as meeting the ATEX requirements for Zone 2.
Unlike "arrester" type products,
the OVP2 is a solid-state switching device with full ratings for
AC fault current and high levels of lightning surge current. As
the device goes into conduction at low voltage, it provides much
better protection than gapped devices or metal-oxide varistors.
Note: the OVP2 is not
recommended where steady-state AC voltage exists between the
connection points, typically induced AC voltage.
Features
& Characteristics
- The only fail-safe
"arrester" on the market (i.e.. fails shorted).
- Solid-state design
eliminates arcing.
- Conduction at much lower
voltages than gapped arresters.
- Rated for AC fault current
and lightning surge current.
- Suitable for submersed or
above-ground locations.
- UL, C-UL listed Div. 2
design, CE marked for ATEX compliance.
- Corrosion-free, lightweight
molded housing.
Typical
Applications
- Insulated Joint Protection
- Airport Fueling Systems
Isolation / Bonding
- Decoupling Equipment Grounds
|

Specifications
Threshold Voltage (absolute)
-2/+2V (standard)
-Up to -3/+1V (optional)
Lightning Surge Current
100 kA crest (4 x 10 µs waveform) for 5.0 kA, 3.7KA and 2.0 kA
models
75 kA crest (4 x 10 µs waveform) for 1.2 kA models
|
AC Fault Current (Amperes - rms) @ 50/60 Hz |
|
Model |
1 cycle |
3 cycles |
10 cycles |
30 cycles |
5.0 kA
3.7 kA
2.0 kA
1.2 kA |
8,800
6,500
5,300
2,100 |
6,800
5,000
4,500
1,600 |
5,700
4,200
3,700
1,400 |
5,000
3,700
2,000
1,200 |
Environmental rating: IP-68 -
Submersible to 2 m depth.
Hazardous (classified) areas: Per NEC, CSA: Class I, Division 2, Groups A, B, C, D Per EN50021: Zone 2
Third-party listings
& approvals: Underwriter's Laboratories (UL) Underwriter's Laboratories - Canada (C-UL)
Demko, CE Mark
Dimensions & installation See
OVP2 drawings
in pdf format
|

| Technical
Comparisons
Comparison of
Dairyland OVP2 to Gapped Arresters
Zinc grounding cells
These cells consist of two zinc
rods, with insulation material to separate them, in a conductive
backfill material, packaged in a bag. The insulation or
separator leaves the zinc rods reasonably close together without
touching. The backfill material, such as bentonite, promotes
conduction and contact with the surrounding earth, as the
package is buried near the points it is connected to. A wire
lead attaches each rod to a point of interest, such as across an
insulated flange, or between a pipeline and ground. The concept
for protection is that the zinc rods will allow separation of
the two structures, and minimize the DC cathodic protection
current flow under normal conditions. Under over-voltage
conditions, the small separation between the rods, and the
conductive backfill will allow current to flow between them,
draining the unwanted current.
There are several ways in which
the zinc grounding cells will not perform very well for this
application. First, the package must be buried. If the
application is protection of insulated joints from over-voltage
(lightning, for example), and the joint is above ground, the
leads that connect to the joint will be at least several feet
each. Under lightning surge conditions, this affords little or
no over-voltage protection to the insulated joint, as leads have
inductance, which lightning sees as a high impedance, and
therefore creates a large voltage drop in the leads. Lightning
protection for insulated joints is best done by locating a
device directly across the joint, which cannot be done with zinc
grounding cells, as compared to the Dairyland OVP2.
Another electrical problem comes
from AC power system fault current. Zinc grounding cells are
generally not sized for handling any significant fault current.
Power laboratory testing to
assure the performance of this product would be challenging, as
this product is placed in service by burying in the earth, which
would be difficult or impossible in a lab setting that could
provide the needed values of lightning surge current or AC fault
current. We have seen no test data for these products.
By separating the zinc rods in
the package to achieve isolation, the question arises as to what
voltage is allowed by the cell. Separation of two metallic
surfaces by a medium (air, gases, solid insulation,
semi-conductive backfill) has been common for over-voltage
protection, but consistency of performance is an issue. Having
the separation be consistent, producing a known, fixed clamping
voltage is difficult if the product can vary in dimensions or
construction. Consistency in over-voltage protection using a
zinc grounding cell is in question, just as a spark gap arrester
in air can vary during atmospheric changes due to moisture.
In addition, where the desire is
to provide the lowest possible over-voltage on the structure
during an event, a device should have a low impedance for
conduction of current. This is not the case with a zinc
grounding cell.
Dairyland OVP2 (Over-Voltage Protector 2)
As a comparison to the above
description, consider the characteristics of the solid-state OVP2.
It is a blocking device in the normal mode. For all signals
including DC (cathodic protection) current, it presents a very
high impedance up to several volts, then appears as a short
circuit for disturbances. When the event is over, the device
automatically reverts to blocking DC current. There is no
internal gap in the device, so over-voltage clamping occurs at a
very low voltage - much lower than any other technology.
Consistency in performance is assured through the use of tested
power semiconductor components. The device has been designed so
that it will even fail as a short circuit if exposed to currents
beyond the rating, providing a fail-safe nature. The OVP2 has
been tested in a power laboratory and is rated for lightning
surge current and AC fault current.
Comparison of
Dairyland OVP2 to spark gap arresters
Arrester:
Typical terms: gas tube arrester, spark-gap arrester
General Information
When the voltage across a spark gap arrester gets high enough,
an arc bridges the two electrodes, establishing a current path.
Spark gaps are designed to limit the voltage due to transient
conditions, such as caused by lightning.
Most, if not all, spark gaps used
in the cathodic protection (CP) industry are not designed to
carry AC fault current, so they should only be used in
applications where the breakdown voltage of the spark gap to AC
voltage is above any peak AC voltage that might be expected.
(Most other arrester products are also not designed to carry AC
fault current.) From reviewing data sheets of commonly used
spark gaps, the AC breakdown voltage is typically from several
hundred to about one thousand volts.
A common application in the CP
industry is that of providing over-voltage protection for
insulated joints in pipelines carrying flammable materials.
Insulated joints in such pipelines are generally classified as a
Class I, Division 2 hazardous. When these pipelines are in the
same corridor as electric power transmission lines, the AC
voltage that can be imposed on a pipeline due to a
line-to-ground fault at a nearby transmission tower, can be
significantly higher than the AC breakdown voltage of the
protective device at a nearby, or even fairly remote, insulated
joint; thereby allowing significant AC fault current to flow
through the protective device. For this reason, the U.S.
Pipeline Safety Regulations (which regulate the pipeline
industry in the U.S.), requires that insulated joints in
pipelines be protected, and that they be protected against
damage due to lightning and AC fault currents. (Section 192.467
(e) and (f) of these regulations.)
During lightning conditions,
typical spark gaps have a breakdown voltage ranging from several
hundred to over several thousand volts. These arresters have
lightning current ratings from 30,000 to 100,000A peak which
cover virtually all requirements.
It should be recognized that
there is a very significant difference between a peak lightning
current of some value versus an AC current of the same value.
Lightning current is extremely short in duration relative to
even 1/2 cycle of AC current; hence, there is very significantly
more energy associated with AC fault current than with lightning
current. A single lightning stroke reaches its peak current and
is dissipated within about 50 microseconds whereas a typical AC
fault will not be cleared until at least 3 cycles or about
50,000 microseconds. Spark gap arresters, and most other
conventional lightning arresters, are not capable of handling
the significantly higher energy associated with even very low
levels of AC fault current.
Another key factor in insulated
joint applications is the type of insulated joint being
protected. In the Western hemisphere, the most common insulated
joint is one that is field assembled using bolted flanges and
insulation kits. Although voltage breakdown values are published
for the insulation material used in these kits, no manufacturer
of these kits provides a voltage withstand value for the
finished insulated joint; namely, because there are too many
variables which are out of their control. Further, due to the
undesirable electrical geometry of most bolted type insulated
joints (i.e., sharp corners, minimal distance between flanges,
etc.) there is minimal correlation between the actual voltage
withstand capability between adjacent flanges and the voltage
breakdown values of the insulation material used in the
insulation kit.
For the above reasons, when
providing over-voltage protection for typical bolted-type
insulated joints, the optimum over-voltage protector will begin
providing protection at the lowest allowable voltage level. In
most applications, this is just above the maximum voltage
expected across the insulated joint, which is typically the DC
cathodic protection voltage.
By comparison, monolithic (i.e,
factory fabricated) insulated joints are available with known,
and considerably higher, voltage withstand values than most
bolted insulated joints. Electrically, these joints are superior
and accordingly are significantly more expensive. They are still
subject to over-voltage failure.
Dairyland OVP2 (Over-Voltage
Protector 2):
For CP applications where the absolute voltage (i.e., DC plus
peak AC) between the points to be protected is within the
blocking voltage rating of the OVP2, the OVP2 is recommended. Its
characteristics and ratings relative to typical arrester
products are described below. If the absolute voltage between
the planned connection points is greater than the capability of
the OVP2, then the DEI solid state Polarization Cell Replacement
product, described in the following section, should be
considered.
The OVP2 is a solid-state,
bi-directional, over-voltage protection device that blocks both
AC and DC up to a predetermined voltage threshold. Standard
threshold levels are -2/+2 volts, with various
combinations up to -4/+1 volts available upon request. The
instant the voltage attempts to exceed the threshold value
selected, voltage clamping begins and current is readily allowed
to flow through the OVP2.
The OVP2 has the following
standard ratings:
Blocking threshold voltage: -2/+2V Standard
Lightning current: 100,000A peak (4 x 10 waveform)
AC Fault Current (30 cycles): 3,700A (50/60 Hz)
There is no steady-state AC
current rating because the OVP2 is not recommended where the
steady-state AC voltage will put the OVP2 in continual
conduction. This would cause partial rectification of the AC
waveform and could adversely affect CP levels.
Instead of waiting until the
voltage is hundreds to several thousand of volts, the OVP2 begins
voltage clamping just above the blocking threshold voltage, a
significant advantage for personnel safety and for applications
such as insulated joint protection. There is no arcing within
the OVP2 since it uses all solid-state components. Voltage
clamping is instantaneous. Under AC fault conditions, the OVP2
will limit the voltage to less than 10 volts peak under maximum
rated fault current. Under lightning current conditions, the OVP2
will limit the voltage directly across its terminals to less
than 100 volts at 100,000 amperes peak. When taking into account
the effect of lead induced voltage, the voltage across a typical
insulated joint under maximum rated lightning current would be
on the order of 1250 volts. The OVP2 is designed to be installed
with the shortest possible lead length to minimize the voltage
drop in the lead caused by L(di/dt) effect, where L is the lead
inductance per unit length and di/dt is the rate of change of
current, which is extremely high for lightning. Most other
manufacturers of protective devices do not mention the very
adverse effect of lead length, a point that DEI highly
emphasizes in its literature. For most insulated joint
applications, the OVP2 can, and should, be installed with a total
lead length of about 6” (150 mm). For more information on this
subject, request DEI’s article on the effects of lead length.
An important safety feature
regarding the design of the OVP2, is that it is “fail-safe.” If
exposed to current values beyond rating so that failure occurs,
failure will occur in the shorted mode (i.e., fail as a short
circuit). In the shorted mode, the OVP2 still meets all current
ratings but it will not be blocking DC current. This assures
over-voltage protection and personnel safety at all times. Most
known spark gap and other lightning arresters used in the CP
industry will fail as an open circuit when tested to failure.
The OVP2 is UL listed for Class 1,
Division 2 hazardous locations, Groups B, C, and D and is
packaged in a NEMA 6P (IP68) explosion-proof, submersible
enclosure.
Summary of benefits of the OVP2
versus most lightning arresters:
- Much lower threshold
voltage.
- AC fault current rated.
- Clamps voltage to much lower
levels.
- Fail-safe.
- Known, fixed parameters.
- UL listed for Class I, Div.
1 & 2 hazardous locations.
- UL listed as an over-voltage
protective device for lightning current.
- Explosion proof, NEMA 6P
(IP68) enclosure.
- DEI has test data that shows
the total voltage drop of the OVP2 plus leads. Other devices
only publish data regarding the product alone.
|
|