Navigation:
Home >
Products >
Instruments >
Field Service
Instruments >
Clamp-Style Meters & Current Clamps
Amprobe ACDC-100
1000A AC/DC Clamp-On
Digital Multimeter

Clamp-on multimeter for AC & DC voltage to
600V,
DC current to 1000A,
AC current to 800A,
plus ohms, capacitance & diode test.

Description
Amprobe’s ACDC-100 AC/DC Digital
Clamp-On Multimeter is where
accuracy, quality, and newest technology meet. The ACDC-100 offers
superior AC/DC measurement capabilities, highest product quality and
enhanced ergonomics with Red, Rubber, Ribs™ design.
|

|
|
Features
- 1000A DC current, 800A AC
current
- Large, easy-to-read LCD display
- Auto and manual ranging
- Relative zero mode
- Auto power off
- Data hold
- MAX capture function for inrush
current measurements (30 ms response)
- Diode Test
- Audible continuity
- Accommodates conductors up to
2.00” (50 mm) in diameter
- "Third hand" - test probe holder
- Rubber over-molded case with
built-in probes storage
- Carrying case, test leads,
batteries (installed) and user manual included
- Wide choice of
Amprobe multimeter
accessories
|

|
DC Voltage Ranges |
400.0 mV, 4.000, 40.00, 400.0 V, 600 V |
|
DC Voltage Accuracy |
± 0.5% rdg ± 3 digits |
|
AC Voltage Ranges |
400.0 mV, 4.000, 40.00, 400.0 V, 600 V |
|
AC Voltage Accuracy |
± 1.5% rdg ± 4 digits |
|
Input Impedance |
10 MΩ |
|
Transient Protection |
6.5 kV (1.2 / 50 μs surge) |
|
DC Current (clamp-on) |
400.0, 1000 A |
|
DC Current Accuracy |
± 1.5% rdg ± 4 digits |
|
AC Current (clamp-on) |
400.0, 800 A (50-500 Hz) |
|
AC Current Accuracy |
± 1.5% rdg ± 5 digits |
|
Overload Protection |
1000 A dc or 800A rms continuous |
|
Resistance Ranges |
400.0 Ω, 4.000, 40.00, 400.0 kΩ, 4.000,
40.00 MΩ |
|
Capacitance Ranges |
50.0, 500.0 nF, 5.000 μF, 50.00 μF, 500.0 μF,
3000 μF |
|
Diode Test |
< 1.6 VDC @ 0.4 mA |
|
Audible Continuity Test |
Between 10 Ω and 120 Ω |
|
Display |
3-3/4 digit (4000 count) LCD
display |
|
Update Rate |
3 per second |
|
Polarity |
Automatic |
|
Operating Temperature |
0°C to 40°C |
|
Relative Humidity |
< 80% RH up to 31°C decreasing to 50% RH at
40°C |
|
Altitude |
Operation below 2000 m. Indoor use. |
|
Storage Temperature |
-20°C to 60°C, < 80% RH (with battery
removed) |
|
Low Battery |
Below approx. 2.4V |
|
Power Supply |
Two 1.5V AAA Size (NEDA 24G or IEC R03)
batteries or two 1.5V AAA Size (NEDA 24A or IEC LR03)
alkaline batteries. |
|
Power Consumption |
Typical 11 mA for ACA/DCA
and 2.9 mA for other functions |
|
Auto Power Off |
After being idle for 30 minutes |
|
Max Conductor Diameter |
50 mm (2.00 in) |
|
Special Features |
30ms Max Hold; Data Hold; Relative Zero
mode |
|
Dimensions |
227x 78 x 40 mm (8.9 x 3.1 x 1.6 in) |
|
Weight |
290 gm
(10 oz) |
|
Safety |
Meets EN61010-1:2001;
IEC61010-2-032(2002), EN61010-2-032(2002),
UL61010B-2-032(2003), Category III 600 Volts AC & DC. |
|
Related Products |
Amprobe