Amprobe AM-160-A TRMS
Precision True RMS Digital
Multimeter
with PC Connection

Top-of-the-line, affordable digital
multimeter for professional environments.
AC & DC voltage to 1000V, AC & DC current to 10A, plus resistance,
frequency, capacitance, duty cycle & more.

Amprobe
Model
AM-160-A TRMS is a replacement for Amprobe Model AM-160, which was declared obsolete
on April 16, 2010. The descriptions, specs and picture in this web page still
reflect the AM-160.
Description
The Amprobe AM-160-A TRMS True RMS digital
multimeter (DMM) offers all capabilities of the
Amprobe AM-140 TRMS True RMS
Digital Multimeter, but with higher accuracy. The AM-160 also
accepts dual Type-K thermocouples for temperature measurement from
-58 to +1832°F or -50 to +1000°C. Both the AM-140 and AM-160-A offer an optical RS232 PC interface and meet the needs of technicians testing electrical
circuits up to 1000V and 10A, as well as the needs for testing components and digital logic. Component test
capabilities include resistance, capacitance, frequency,
diode test, and continuity. Circuit test capabilities include duty
cycle, logic test, and dBm.
Features
- True RMS
- Optically isolated RS232 PC
interface
- Six-digit display
- MAX, MIN MAX-MIN recording
- Peak hold
- Auto and manual ranging
- Intelligent auto power off
- Data hold
- Relative zero mode
- Audible and visual warning against
improper plug-in
- DC Loop Current 4-20mA
- dBm reading with 20 selectable
impedance value
- Backlight display
- Large, easy to read LCD display
- Diode test
- Audible continuity test
- Safety: CAT III 1000V, CAT IV 600V
- Wide choice of
Amprobe multimeter
accessories, including dual thermocouple channels.
 |

|
DC Voltage Ranges |
500.00 mV, 5.0000V, 50.000V, 500.00V,
1000.0V |
|
DC Voltage Accuracy |
±0.05% rdg ± 2 lsd |
|
True AC
RMS Voltage Ranges |
500.00 mV, 5.0000V, 50.000V, 500.00V,
1000.0V |
|
AC Voltage Accuracy |
±0.8% rdg
± 20 lsd |
|
DC Current Ranges |
500.00 μA,
5000.0 μA, 50.000 mA, 500.00 mA, 5.0000A, 10.000A |
|
DC Current Accuracy |
±0.5% rdg
± 20 lsd |
|
AC Current Ranges |
500.00 μA,
5000.0 μA, 50.000 mA, 500.00 mA, 5.0000A, 10.000A |
|
AC Current Accuracy |
±0.5% rdg
± 50 lsd |
|
True AC RMS Coupling |
AC or AC + DC |
|
True AC RMS Crest Factor |
5:1 at full scale |
|
Overload Protection |
Fast-blow fuses |
|
Resistance Ranges |
500.00
Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ,
50.000 MΩ |
|
Temperature Measurement |
Dual Type-K thermocouple,
-58 to +1832°F or -50 to +1000°C. |
|
Frequency Range |
5.0000 Hz to 200.000 kHz |
|
Capacitance Ranges |
50.00 nF, 50.00 nF, 5.000 µF, 50.00 µF, 500.0 µF,
9999 µF |
|
Duty Cycle Measurement |
0.1% to 99.99%, 5V logic, 5 Hz to 500 kHz |
|
4-20 mA Current Loop Test |
0-100% of span |
|
Continuity Test |
Audible indication at <
40 Ω in 100 ms |
|
Diode Test |
0.8 mA, 3.5 Vdc |
|
Display |
5-4/5 digits (50000 count)
backlit LCD
display plus 42-segment bar graph |
|
Measurement Rate |
5 times per second in fast mode (4-4/5
digit display)
1.25 times per second in stable mode (5-4/5 digit
display) |
|
Operating Temperature |
0°C to 45°C (32°F to 113°F)
at < 70% RH |
|
Storage Temperature |
-20°C to 60°C, < 80% RH (with battery
removed) |
|
Power Supply |
9V alkaline battery, NEDA
1604, JIS 006P, IEC 6F22 |
|
Battery Life |
150 hours typical
with
alkaline |
|
Dimensions |
196 x 97 x 46 mm (7.7 x
3.8 x
1.8 in) |
|
Weight |
390 g
(14 oz) with battery |

|
ACF-3000 AK |
3000A AC Flexible Clamp-on
Attachment |
|
A-1000 |
1000A TRMS AC/DC Clamp-on
Attachment |
|
CT-600 AC/DC |
600A AC/DC Clamp-on
Attachment |
|
A400 |
400A AC Clamp-on Attachment |
|
CT-30 |
Milli-Amps to 30A AC/DC Clamp-on Attachment |
|
DKTA-620 and two of TPK-56 |
Dual input Thermocouple adapter with two
thermocouples -50°F to 600°F
(AM-160-A TRMS Only) |
|
VRC-320 |
Alligator Clips (for test leads) |
|
RS-232 KIT1 |
PC Interface kit (PC connection cable with
software) |
|
RS-USB |
USB to RS-232 Adapter |
|
CC-ACDC |
Carrying Case |
|
Replacement Parts
(supplied with product)
|
|
TPK-59 |
Type-K thermocouple (AM-160-A TRMS only) |
|
MTL-90B |
Test leads with set of
alligator clips (alligator clips are not supplied with
product) |
|
FA-1A/1000V |
Fuse 1A/1000V IR 10kA for mA/uA
terminal (AM-160-A TRMS) |
|
FA-15A/1000V |
Fuse 15A/1000V IR 10KA or
11A/1000V IR 20kA for Amp terminal (AM-160-A TRMS) |
|
|
Instruction Manual |
|