Navigation:
Home >
Products >
Instruments >
Diagnostic
Instruments >
Data
Loggers & CP Survey Equipment
Bullhorn® CP
Logger
by American
Innovations

|
 |
- Low-cost
- Adjustable Input Ranges
- Small
- Rugged
- Weatherproof
- Easy-to-use
- Can log up to 10 days at a
time
- Time stamped data
|

|
Description
American Innovations is now offering
the Bullhorn® i-series CP Logger, a small, rugged device ideal
for taking cathodic protection measurements using a high
impedance, filtered input. Potential applications include:
-
Pipe-to-soil
readings for depolarization studies
- Stray current interference
studies
- Verifying polarization
during interruption surveys
- Logging rectifier output
current, voltage or bond current.
- Any logging application that
requires multimeter type DC input characteristics.
The CP Logger has adjustable
input ranges (1-100 mV, 1-10 V and 0-100 V) with excellent
resolution and accuracy. Battery life is sufficient for up to
ten days. It can be used in conjunction with AI’s MicroMax
GPS200 current interrupter for interference surveys.
The AI CP Logger is easy to use
and setup. It comes with software for installation, downloading,
and data analysis/presentation. See next page for Technical
Specifications. |
|

|
Voltage Range |
User selectable with
6 position DIP switch for 0 to 100 mV, 1 to 10 V, 0 to 100 V. Note:
If the need is to capture positive and negative readings simultaneously, use two MicroLoggers. |
|
Voltage Resolution |
0.05 mV (0-100 mV range), 1 mV (0-10 V range), 10 mV
(0-100 V range). |
|
Voltage Accuracy |
±
0.1% FSR
typical. |
|
Voltage Calibration |
On board factory calibration.
User digital calibration available through software.
Calibration correction value stored in device. |
|
Input Impedance |
10 Mohm, minimum |
|
Filtering |
2 Hz low-pass filter |
|
Recording Interval |
1 second, 2 seconds, 5 seconds, 15 seconds, 30
seconds, 1 minute, 5 minutes, 10 minutes, 15 minutes,
30 minutes, 1 hour,
2 hours, 4 hours,
8 hours,
12 hours |
|
Memory |
32,768 data points,
non-volatile memory. |
|
Power (logger board) |
User replaceable 3.5 V lithium battery.
1 year typical life for continuous logging. |
|
Time Accuracy |
± 1 minute per month at 20ºC. |
|
Data Format |
User-defined engineering units.
Date & time stamped. |
|
Red Visual Indicator |
Red Led flashed at the reading interval to indicate
device is operational. |
|
Input Connection |
Banana jacks, red (+) and black (-). |
|
Computer Interface |
PC serial or RS232C COM (IFC1000 cable, not
included). |
|
Weight |
10.5 oz without AA batteries |
|
Dimensions |
5-7/16" x 4-1/16" x
1-11/16" |
|
Operating Environment |
-40°C to 75°C, 0 to 95% Relative Humidity. |
|
Enclosure |
Pelican™ case
enclosure, watertight and crushproof with lanyard attachment. |
|