Fluke 373, 374, 375, 376, 381, 365
Clamp Meters

The most advanced family of
Fluke clamp meters ever.
Replacements for Fluke 333, 334, 335, 336, 337.


Description
The new line of Fluke
clamp meters, introduced in September 2010,
addresses needs that electricians and technicians
have been waiting for in clamp meters from Fluke.
They solve classical problems:
- Tight cabinets and
bundled wires that make it difficult to use a
regular clamp meter.
- Large or awkward
conductors a regular clamp meter can’t get around to
measure.
- Needing a
co-worker’s help to get a measurement.
- Wanting to measure
more than 1000 Amps AC.
The new clamp meters
address all of these common problems, plus more -
reducing frustrations and addressing unique needs -
all with the quality and accuracy that user can
only get from Fluke tools. Fluke stands behind these
products, only making the best
|
 |
Who uses them?
- Industrial
maintenance technicians
- Control technicians
- Electricians - in
house
- Electrical and HVAC
contractors
|
What are they used on?
- Industrial equipment
- Industrial controls
- Electrical systems
- Commercial /
industrial HVAC
|

 |
 |
 |
 |
 |
|
Fluke 373 |
Fluke 374 |
Fluke 375 |
Fluke 376 |
Fluke 381 |
 |
|
Fluke 365, a basic
troubleshooting tool |

|
Product |
Key Feature 1 |
Key Feature 2 |
Key Feature 2 |
|
373 |
True-rms and state of the art signal processing allows
for use in noisy electrical environments while providing
stable readings on non‑linear signals. |
Large, easy to read, backlight display automatically
sets the correct measurement range so you do not need to
change switch positions while
taking a measurement. |
Capacitance for troubleshooting start and run motor
capacitors. |
|
374 |
600 A ac and dc current measurement and CAT III 1000 V,
CAT IV 600 V safety rating allows you to work wherever
the job takes you. |
Proprietary inrush measurement technology to filter out
noise and
capture motor starting current exactly as the circuit
protection sees it |
Compatible with iFlex flexible current probe to expand
the measurement range to 2500 A ac while providing
increased display flexibility, ability to measure
awkward sized conductors and improved wire access. |
|
375 |
Increased measurement functionality with increased
resistance range, frequency measurement and mV dc to
interface with other accessories |
Integrated low pass filter and state of the art signal
processing allows for use in noisy electrical
environments while providing stable readings. |
|
|
376 |
2500 A ac current measurement with iFlex flexible
current probe (included). |
1000 A ac and dc current
measurement with fixed Jaw. |
1000 V ac and do voltage measurement. |
|
381 |
Wireless technology allows the display to be carried up
to 30 ft. away from the point of measurement for added
flexibility without interference with measurement
accuracy. |
2500 A ac current measurement with
iFlex flexible current probe (included). |
The removable magnetic display can be conveniently
mounted where it is easily seen |
|
365 |
Small, detachable jaw makes accessing wires and viewing
the display easier. |
True-rms 200 A ac and dc current measurement. |
Built in flashlight/torch allows for easy illumination
and identification of wires. |
|
i2500-10/18 |
Allows upgrade of compatible meters to 2500 A ac current
measurement capability. |
Ability to measure awkward sized conductors and improved
wire access. |
6 ft cable provides increased display flexibility. |

|
|
Fluke 381 |
Fluke 376 |
Fluke 375 |
Fluke 374 |
Fluke 373 |
Fluke 365 |
|
iFlex flexible
current probe |
Included |
Included |
Compatible |
Compatible |
- |
- |
|
AC current(jaw) |
Range |
999.9A |
999.9A |
600.0A |
600.0A |
600.0A |
200.0A |
|
Accuracy |
2% ± 5 dig. |
2% ± 5 dig. |
2% ± 5 dig. |
2% ± 5 dig. |
2% ± 5 dig. |
2% ± 5 dig. |
|
AC current(iFlex) |
Range |
2500.0A |
2500.0A |
2500.0A |
2500.0A |
- |
- |
|
Accuracy |
3% ± 5 dig. |
3% ± 5 dig. |
3% ± 5 dig. |
3% ± 5 dig. |
|
|
|
DC current |
Range |
999.9A |
999.9A |
600.0A |
600.0A |
- |
200.0A |
|
Accuracy |
2% ± 5 dig. |
2% ± 5 dig. |
2% ± 5 dig. |
2% ± 5 dig. |
|
2% ± 5 dig. |
|
AC voltage |
Range |
1000.0V |
1000.0V |
600.0V |
600.0V |
600.0V |
600.0V |
|
Accuracy |
1.5% ± 5 dig. |
1.5% ± 5 dig. |
1.5% ± 5 dig. |
1.5% ± 5 dig. |
1% ± 5 dig. |
2% ± 5 dig. |
|
DC voltage |
Range |
1000.0V |
1000.0V |
600.0V |
600.0V |
600.0V |
600.0V |
|
Accuracy |
1% ± 5 dig. |
1% ± 5 dig. |
1% ± 5 dig. |
1% ± 5 dig. |
1% ± 5 dig. |
2% ± 5 dig. |
|
mV dc range |
- |
500mV |
500mV |
- |
- |
- |
|
Resist-ance |
Range |
60,000 Ω |
60,000
Ω |
60000
Ω |
6000
Ω |
6000
Ω |
6000
Ω |
|
Accuracy |
1% ± 5 dig. |
1% ± 5 dig. |
1% ± 5 dig. |
1% ± 5 dig. |
1% ± 5 dig. |
1% ± 5 dig. |
|
Capaci-
tance |
Range |
- |
1-1000 µF |
1-1000 µF |
1-1000 µF |
10-1000 µF |
- |
|
Accuracy |
- |
1% ± 4 dig. |
1% ± 4 dig. |
1% ± 4 dig. |
2% ± 2 dig. |
- |
|
Continuity |
< 30
Ω |
< 30
Ω |
< 30
Ω |
< 30
Ω |
< 30
Ω |
< 30
Ω |
|
Frequency |
5-500 Hz |
5-500 Hz |
5-500 Hz |
- |
- |
- |
|
Remote Display |
Yes |
- |
- |
- |
- |
- |
|
AC response |
True-rms |
True-rms |
True-rms |
True-rms |
True-rms |
True-rms |
|
Backlight |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Data hold |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Min/Max/Avg |
Yes |
Yes |
Yes |
Yes |
- |
- |
|
Inrush |
Yes |
Yes |
Yes |
Yes |
- |
- |
|
Size (HxWxD) |
280x88x50 |
248x85x45 |
248x85x45 |
248x85x45 |
232x85x45 |
225x65x46 |
|
Max wire diameter |
750 MCM |
750 MCM |
750 MCM |
750 MCM |
750 MCM |
4/0 |
|
Weight (g) |
540 |
375 |
375 |
375 |
370 |
275 |
|
Category rating |
CAT III
1000 V,
CAT IV
600 V |
CAT III
1000 V,
CAT IV
600 V |
CAT III
1000 V,
CAT IV
600 V |
CAT III
1000 V,
CAT IV
600 V |
CAT III
600 V,
CAT IV
300 V |
CAT III
600 V, |
|
Warranty |
3 years |
3 years |
3 years |
3 years |
3 years |
3 years |
|