Model B3A2
Dual-Channel Analog Multimeter
by MC Miller Co.


Advantages
- Designed for the corrosion control industry
- Increased dependability through solid state design
- RFI shielded throughout
- Accurate, stable readings
- Active filtering for power frequency rejection
- Selectable input resistance
- Withstands the harshest environments
- Flexible multimeter for all your corrosion tests
General Information
- A major design achievement was to eliminated the effects of
RFI, and offer accurate, repeatable readings.
- Impact resistant d'Arsonval meters with taut band movement
to withstand rough handling.
- Resistant to rain, dust and temperature: - 0°F to 150°F.
- 10% up scale: -0.1, 0, 1; -.02, 0, 2: a visual prompt which
indicates when the reading crosses zero.
- Knife edge pointer with easy-to-view mirror scale
- Accuracy: +0.5% of full scale for all ranges.
- Tracking accuracy: +0.5%.
|

Specifications
Left Meter
- 9 DC voltage ranges, zero to full scale:
2 mV, 10 mV, 20 mV, 100 mV, 200 mV, 1 V, 2V, 10V, 100V.
- Minus 10% of full scale on all ranges.
- Input polarity reversal switch on volts and amps ranges
eliminates the need to reverse test leads.
- Best resolution: 20 micro volts (0.00002 V) on the 2 mV
range.
- Input Resistance:
10,000 Ohms on 2 mV and 10 mV ranges.
10 Megohms on 20 mV to 100 V ranges.
- Line frequency rejection: >60 dB @ 60 Hz.
- RF rejection: > 70 dB @ 1 MHZ.
- Overload protection: 10 times full scale.
- 9 DC ampere ranges, zero to full scale:
2 mA, 10 mA, 20 mA, 100 mA, 200 mA, 1A, 2A, 10A, 20A.
- Minus 10% of full scale on all ranges.
- Best resolution: 20 microamps on the 2 mA range.
- Burden voltage: 20 mV.
- Overload allowed: 5 times full scale, less than 5 sec.
- Contact check: > 200 mA short circuit.
- Adjustable output current supply: controllable 0 to 3 VDC
and 0 to 4 amps.
- Control external current flow with built-in 25 watt
adjustable rheostats.
- Read internal battery voltage directly.
- Left meter switch: internally connects right meter to left
terminals, enabling current and voltage to be read simultaneously.
Right Meter
- 9 DC voltage ranges, zero to full scale:
2 mV, 10 mV, 20 mV, 100 mV, 200 mV, 1V, 2V, 10V, 20V.
- Minus 10% of full scale on all ranges.
- Input polarity reversal switch on volts.
- Best resolution: 20 microvolts (0.00002 V) on the 2 mV
range.
- Input resistance:
100,000 Ohms on 2 mV and 10 mV ranges.
Selectable from 1 MOhm, 10 MOhms, 25 MOhms, 50 MOhms, 100 MOhms, 200 MOhms on 20 mV to 100
V ranges.
- Line frequency rejection > 60 dB @ 60 Hz.
- RF rejection > 70 dB @ 1 MHZ.
- Bias control + full scale, all ranges.
- Overload protection 10 times full scale.
Applications
The B3A2 was designed specifically as a cathodic protection
test instrument. In most cases it is all that is required for the test and evaluation of
existing systems or design of new installation. It can be utilized in making the following
tests, which are illustrated in the B3A2 operating manual:
- Structure-to-soil potentials. Current measurements (direct
null-amp method, 2 or 4 terminal zero resistance)
- IR drops and calibration of IR drop test stations.
- Soil or water resistivity by soil box and by 4-electrode
method.
- Soil potential gradients.
- Continuity tests.
- Pipe coating resistance tests and fault surveys
(over-the-ground method).
- Galvanic anode rectifier output and cathodic protection
interference tests.
- Duct slug survey on lead covered cables and concrete bridge
deck surveys.
- pH determination.
- Grounding tests.

|
|