Model M-3-A2
Dual-Channel Analog Multimeter
by MC Miller Co.

Advantages

  • Completely solid state
  • Selectable input resistance
  • Overload protection (even on 1 mV range)
  • Both instruments identical
  • Accurate
  • Extremely rugged
  • Low maintenance costs

Center Zero

  • Right voltmeter: Taut-band instrument driven by amplifier. 9 voltmeter ranges from 1 mV to 10 V and selectable input resistances from 1 to 200 MOhm.
  • Left voltmeter: Taut-band instrument driven by amplifier. 9 voltmeter ranges from 1 mV to 50 V; 8 milliammeter / ammeter ranges 1 mA to 10 A (20 mV drop shunts). Built-in IR drop contact checking circuit.

Voltmeters with Amplifiers

  • Right voltmeter: Selectable input resistances of 1, 10, 25, 50,100 & 200 MOhm on ranges from 10 mV through 10 V. 1 and 5 mV ranges have fixed resistance of 1000 Ohms.
  • Left voltmeter: 10 MOhm input resistance on all ranges from 10 mV through 50 V. l and 5 mV ranges have fixed resistance of 1000 Ohms.
  • Solid State integrated-circuit amplifier.
  • Operated by easy-to-replace penlite cells with long shelf-life.
  • Temperature compensated.
  • Operating range 0oF to 150oF.
  • Short warm-up time.
  • Good response time on all ranges.
  • Very stable zero. No need to readjust zero when changing ranges (except for 1 and 5 mV ranges).
  • AC filters rejects 60 Hz power system potentials up to 35 VAC.

Selectable Input Resistance

Right voltmeter: Input resistances of 1,10, 25, 50,100 & 200 MOhms selectable by rotary switch. Selectable input resistance permits detection of high resistance in the external circuit and the elimination of resulting errors in nearly all cases. A very important factor in structure to earth potentials, where errors in reading can be very costly. Note: Does not function on the 1 and 5 mV ranges, which have a fixed resistance of 1000 Ohms.

Overload Protection

Advanced design features virtually eliminate the chance of damage to either meter from electrical overload on all volt and millivolt ranges, even the 1 mV range. Tests indicate that the M-3-A2 will withstand AC or DC voltages far in excess of any encountered in normal field testing. Note that the ammeter shunts are not protected by the amplifier, and are therefore subject to damage by current overloads.

Instruments

The instruments are special taut-band, high-torque type built to rigid MC Miller Co. specifications. The instruments are inherently more resistant to mechanical damage, and since both instruments are identical, one spare instrument can be used as a replacement for the other. Replacement instruments, if ever needed, are low in cost and readily available. Scales have clearly marked 110 divisions from end to end (0.5 V to 0 to 0.5 V and l.l V to 0 to 1.1 V). They are 4.0" long and are of the mirror type. Pointers are knife-edge type. Full scale and tracking accuracy is within 1 1/2% of full scale except for the 1 and 5 mV.

Shunts

Built-in multi-range ammeter shunt has high overload capacity and a high degree of accuracy. Use of optional accessory external shunt extends the range of current measurements to 100 A and can be used with either meter.

Contact Checking Circuit

A built-in I-R drop contact checking circuit is used to determine when good low-resistance contacts are obtained. Circuit may also be used like an ohmmeter for checking continuity of test leads.


 

Instruments & Test Equipment

 Hand-held Multimeters
 Current Clamps & Meters
 Portable Multimeters
 Potential Meters
 Dataloggers & CP Survey
 Current Interrupters
 Power Supplies
 Soil Resistance Meters
 Pipe & Short Locators
 Insulation Testers
 Short - Holiday Detectors
 Coating Thickness Gauge
 Ultrasonic Thickness G.
 Test Reels & Wire

  

Cathodic Protection Products & Materials

 Impressed Anodes
 Sacrificial Anodes
 Cable & Splicing
 DC Supplies & Rectifiers
 Remote Monitoring
 Polarization Cells
 Overvoltage Protection
 Junction & Bond Boxes
 Test Stations & Markers
 Reference Electrodes
 Test Instruments
 Insulating Materials
 Pipe Coatings & Tape
 Miscellaneous Products

  

Cathodic Protection Services

 Farwest Engineering
 Farwest Installation

  

Cathodic Protection of Offshore Structures

 Galvanic CP Systems
 Impressed CP Systems
 Attachment Systems
 Monitoring Equipment

  

Marine Products Division

 Marine ICCP Systems
 Galvanic CP Materials
 Marine Growth Protection
 Electrolytic De-Scaling
 Electro-Chlorination

  

Pipeline Protection Products Division

 Epoxy Coatings
 Heat-Shrink Coatings
 Mastic Coatings
 Petrolatum Coatings
 Tape Coatings
 Surface Decontamination
 Moisture Seal Products
 Rockshields
 Inspection Instruments
 Insulated Fittings
 Insulators & Seals
 Pipeline Casing Fillers
 Flange Insulation
 Pipeline Cleaning Pigs
 Composite Systems
 Accessory Products
  

More Farwest Website Resources

 Search this Website
 Request Quote
 Order Products Online
 View PDF Catalog
 Industry Links
 Farwest Suppliers
 Industry News
 Employment
  
 

Home

Products Services Search Request Quote Order Online

Farwest Corrosion Control Company
888-532-7937   (888-5FARWEST)

Tel: 

 310-532-9524
Fax:  310-532-3934

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.farwestcorrosion.com

© 1996-2008 Farwest Corrosion Control Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956