M. C.
Miller’s Non-Porous Plug Technology
The “active” (half-cell) solution in an
IonX Portable Electrode (saturated copper sulfate solution) is contained
in a sealed unit that incorporates a non-porous, ionically-conducting
plug. Please see NACE Magazine article
Submersible Reference Elecrodes Revisited.
Features & Benefits
- Same dimensions, fittings
and ceramic tips as standard RE-5 or RE-5C portable
reference electrodes for connection to standard canes and electrode
extensions.
- No copper sulfate solution leakage
(“Green” electrode).
- Half-cell cannot be contaminated by
electrolyte soil elements, such as chloride ions.
- No need to handle, store or dispose of
hazardous copper sulfate crystals or copper sulfate anti-freeze
solutions.
- Electrodes arrive ready-to-use. No need
to prepare chemicals in the field.
- Calibrated at the factory and shipped
with a certificate of calibration.
- Electrode potentials in the range 316 mV
±10 mV at 25°C versus Standard Hydrogen Electrode (SHE).
- Electrodes can be stored at temperatures
down to -20°C.
- Robust, customized ceramic plugs.
- Replacement plug assemblies available
for ordering when required.
Certification
IonX Portable Electrodes are in a
ready-to-use state upon completion of the manufacturing process, and
their electrode potentials are measured at the factory prior to
shipping. A certificate of calibration is issued for each electrode.
This certificate indicates the electrode potential as measured at the
factory, the certification date, and the expiration date, which is 12
months beyond the date of certification. IonX Portable Electrodes can be
returned annually to M. C. Miller for a calibration "check-up."
Calibration "Check-up" Service
As for other equipment, such as
voltmeters, for which annual calibration checking is suggested, M. C.
Miller offers a calibration check-up service (Cat. #14698) for IonX
Portable Reference Electrodes. This service includes a new 12-month
certificate of calibration, which will only be issued a calibration
certificate if its electrode potential falls in the range 316 mV
±
10 mV, versus the Standard Hydrogen Electrode (SHE). Should the external
ceramic plug require replacement to bring an electrode into calibration,
the customer would be informed, and the cost of a replacement plug would
be added to the service cost.
Processing time at the M. C. Miller
facility will be 1-3 business days for the re-calibration service.
Shipping costs are the customer's responsibility. A Return Merchandise
Authorization (RMA) number is required to accompany a returned electrode
and a RMA number can be obtained from our sales department.
Specifications &
Ordering
|
Catalog No. |
Composition |
Max Dia. |
Length |
Weight |
|
IonX RE-5 Cat # 14550 |
CuSO4 |
1.375" |
6.5" |
0.40 lb |
|
IonX RE-5C Cat # 14555 |
CuSO4 |
1.375" |
7.0" |
0.44 lb |
|