Accurately measure corrosion rates of ductile iron (Model DIP-1)
or carbon steel (Model CSP-1) underground and under wrap.

DIP-1 Ductile Iron Probe. Small size, low profile, long life.
 
Description

Model DIP-1 Corrosion Sensor by Tinker & Rasor is an Electrical Resistance (ER) corrosion sensor designed specifically for ductile iron installations. The probe is made of ductile iron with the annealing oxide layer intact for accurate MPY loss rates.

Model CSP-1 Corrosion Sensor by Tinker & Rasor is designed for carbon steel installations.

Both models measure cumulative corrosion and calculate the in-situ corrosion rates. The sensor has a very low 0.1875” (4.76 mm) profile ) and will lay below a polyethylene encasement without interference.

Features

  • Model DIP-1: ductile Iron element with annealing oxide intact.
  • Model CSP-1: carbon steel element (illustrated to right).
  • Works with or without CP applied.
  • Low-profile facilities under polyethylene encasement installation.
  • Compatible with standard ER instruments.
  • 25-foot (7.6 m) cable with weatherproof 6-pin connector.
  • Pigtail-lead for connection to CP.

Construction

  • Element made from ductile iron pipe or carbon steel for accurate corrosion loss readings.
  • Built for harsh underground environments.
  • Measurement span: Nominal 25 mils (0.63 mm)
  • Measurement element area: 1 in2 (6.5 cm2)
  • Cable connections sealed from environment with only the measurement element exposed.
  • Mil-spec, weatherproof 6-pin connector.
  • 10-foot, low-profile ribbon cable (3 m) to end of PE wrap, then 15-foot (4.5 m) round leads to test station.
  • Probe dimensions: 6.00” L x 1.00” W x 0.185” H (154 x 26.8 x 3.8 mm)
  • Compatible with standard all ER probe instrumentation, i.e., Rohrback Cosasco Systems Checkmate™, Ck3 or Ck4, Metal Samples MS0500 and MS1500E, or others.
  • The Tinker & Rasor Model T-3 CP Test Station (shown above) is recommended as the access point for Models DIP-1 or CSP-1.

Applications

  • Use on any buried ductile iron or carbon steel installation with or without CP.
  • Benchmark soil corrosivity and native soil corrosion.
  • Install and measure under Polyethylene Encasement (PE: AWWA C105 Appendix A)

  

Cathodic Protection Products & Materials

  

Cathodic Protection Services

 Farwest Engineering
 Farwest Installation

  

Offshore Products Division

 Galvanic CP Systems
 Impressed CP Systems
 Attachment Systems
 Monitoring Equipment

  

Marine Products Division

 Marine ICCP Systems
 Galvanic CP Materials
 Marine Anti-Fouling
 Electrolytic De-Scaling
 Electro-Chlorination
 Marine CP Monitoring
 Galvanic Isolators

  

Corrosion Control Products Company

  

More Farwest
Website Resources

 Farwest News
 Search this Website
 Request Quote
 Order Products Online
 

Home

Products Services Search Request Quote Order Online

Farwest Corrosion Control Company
888-532-7937   (888-5FARWEST)
Complete Cathodic Protection™

Tel: 

 310-532-9524
Fax:  310-532-3934

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.farwestcorrosion.com

© 1996-2011 Farwest Corrosion Control Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956