Navigation:
Home >
Products >
Test Stations & Junction Boxes
> Coupons
DIP-1 & CSP-1
Corrosion Sensors
for
Ductile Iron & Carbon Steel
by Tinker & Rasor

Accurately measure corrosion rates of ductile
iron (Model DIP-1)
or carbon steel (Model CSP-1) underground and under wrap.

 |
 |
| DIP-1
Ductile Iron Probe. |
Small
size, low profile, long life. |
Description
Model DIP-1 Corrosion Sensor
by Tinker & Rasor is an Electrical Resistance (ER) corrosion
sensor designed specifically for ductile iron installations. The
probe is made of ductile iron with the annealing oxide layer
intact for accurate MPY loss rates.
Model CSP-1 Corrosion Sensor
by Tinker & Rasor is designed for carbon steel
installations.
Both models measure cumulative
corrosion and calculate the in-situ corrosion rates. The
sensor has a very low 0.1875” (4.76 mm) profile ) and will lay
below a polyethylene encasement without interference.
Features
- Model DIP-1: ductile Iron
element with annealing oxide intact.
- Model CSP-1: carbon steel
element (illustrated to right).
- Works with or without CP
applied.
- Low-profile facilities under
polyethylene encasement installation.
- Compatible with standard ER
instruments.
- 25-foot (7.6 m) cable with
weatherproof 6-pin connector.
- Pigtail-lead for connection to
CP.
Construction
-
Element
made from ductile iron pipe or carbon steel for accurate
corrosion loss readings.
- Built for harsh underground
environments.
- Measurement span: Nominal 25
mils (0.63 mm)
- Measurement element area: 1 in2
(6.5 cm2)
- Cable connections sealed from
environment with only the measurement element exposed.
- Mil-spec, weatherproof 6-pin
connector.
- 10-foot, low-profile ribbon
cable (3 m) to end of PE wrap, then 15-foot (4.5 m) round leads
to test station.
- Probe dimensions: 6.00” L x
1.00” W x 0.185” H (154 x 26.8 x 3.8 mm)
- Compatible with standard all ER
probe instrumentation, i.e., Rohrback Cosasco Systems
Checkmate™, Ck3 or Ck4, Metal Samples MS0500 and MS1500E, or
others.
- The Tinker
& Rasor Model T-3 CP Test Station (shown above) is
recommended as the access point for Models DIP-1 or CSP-1.
Applications
- Use on any buried ductile iron
or carbon steel installation with or without CP.
- Benchmark soil corrosivity and
native soil corrosion.
- Install and measure under
Polyethylene Encasement (PE: AWWA C105 Appendix A)
|
|