Navigation:
Home >
Products >
Test Stations & Junction Boxes
> Test Station
Monitoring
Navigation:
Home >
Products >
Remote Monitoring Equipment >
WatchdogCP Products
WatchdogCP
P2S-AC
CP Test Station Monitor &Data Logger
Critical Bond Monitor

Obtains
IR-Free potentials (Instant-OFF) and AC & DC corrosion
current densities at CP Test Stations across your pipeline.

|
Overview
The Watchdog P2S-AC makes it possible to obtain critical CP field data, such as AC corrosion current
density, induced AC voltage, critical bond current, and IR-drop free (instant-OFF) potential, that were previously difficult or costly to measure. Installed at a CP test point with a dual coupon test station or at a critical bond, the P2S-AC delivers accurate and reliable data to the Pipeline Watchdog website via GSM or geostationary satellite telemetry.
The P2S-AC transmits regular readings at a programmable interval, with alarms for out-of-normal conditions. Knowing native potential, ON potential, and OFF potential gives the CP professional powerful data to analyze the effectiveness of the cathodic protection system.
The P2S-AC is the perfect tool to better understand AC corrosion issues. Use it to log data during field studies, then permanently monitor the effectiveness of your AC mitigation system.
The unit can function as a CP data logger, taking and storing measurements as often as every 15 seconds.Use it to perform field studies on variable effects on your CP system such as: changing electric transmission line loads, electric rail effects, crossing pipeline interference, and variable soil conditions. The 2 GB SDRAM card can hold several months of data, which can be transmitted to the user via the GSM/GPRS cellular link or retrieved manually.
APPLICATIONS
• AC corrosion current density measurement
• ON / OFF pipe-to-soil potentials
• Critical bond monitoring
• AC mitigation integrity
• CP field studies – electric rail, transmission line, pipeline crossing influence
• CP test point monitoring
FEATURES
• Pipe-to-soil potential (2 structures)
• IR drop-free (Instant OFF) potential
• Induced AC voltage
• AC current density (displayed in A/m2)
• DC protection current (to protected coupon)
• Bond current (bi-polar directional)
• Cellular or satellite communications
• Field replaceable Lithium battery powered – 3 to 5 year life expectancy
• Easy to use web interface
• Data logger- 2 GB SD-RAM data card
• Verify Induced AC Voltage Safety
• Simplify Compliance Reporting
• Eliminate Travel to Remote Sites
• Ensure 100 mV Polarized Potential
• No Software Required for Watchdog Web Interface
|
| |

|
Part Number |
| GSM Cellular telemetry |
P2SAC-GSM |
| Satellite telemetry |
P2SAC-SAT |
| Operating Environment |
|
Temperature |
-40°C to + 80°C |
|
Humidity |
0 to 95%, non-condensing |
| Enclosure rating |
NEMA-4X polycarbonate |
|
Power |
|
Battery |
Internal lithium thionyl chloride battery pack; non-rechargeable
3-5 year replacement under normal operating conditions |
|
Installation |
| Mounting: |
Universal brackets included for pole, pipeline marker, or post mounting |
| Connection cable: |
7' (2.1m) molded, weatherproof 7-conductor cable included w/ twist-lock
connector to unit |
| Satellite Unit: |
Separate bracket to mount 6" (15 cm) diameter satellite terminal |
| Electrical Connections |
|
Inputs |
Structure #1, structure #2, protected coupon, native
coupon, reference cell, shunt +/- |
|
Telemetry |
| GSM cellular telemetry: |
Quad-band (850/900/1800/1900 MHz) GSM/GPRS |
| Satellite telemetry: |
Inmarsat IsatM2M |
| Data Logging |
|
Memory |
2 GB SD card (4 million + readings = over 12 months of
data at 8 second sample rate). |
|
Website Controls |
|
Remote Monitoring |
Field Configuration (bond/CP test point) Reporting frequency
Alarm limits (upper & lower) |
|
Digital Logging |
Logging interval (15 sec/1min/10 min/ |
|