Farwest Corrosion
Control Company
 

Home Products Services Contact Us Request Quote Order Online

 
   Navigation:  Home > Products > Test Stations & Junction Boxes > Test Station Monitoring
 Navigation:  Home > Products > Remote Monitoring Equipment > WatchdogCP Products

WatchdogCP P2S-AC
CP Test Station Monitor &Data Logger
Critical Bond Monitor


Obtains IR-Free potentials (Instant-OFF) and AC & DC corrosion
current densities at CP Test Stations across your pipeline.

Overview

The Watchdog P2S-AC makes it possible to obtain critical CP field data, such as AC corrosion current
density, induced AC voltage, critical bond current, and IR-drop free (instant-OFF) potential
, that were previously difficult or costly to measure. Installed at a CP test point with a dual coupon test station or at a critical bond, the P2S-AC delivers accurate and reliable data to the Pipeline Watchdog website via GSM or geostationary satellite telemetry.

The P2S-AC transmits regular readings at a programmable interval, with alarms for out-of-normal conditions. Knowing native potential, ON potential, and OFF potential gives the CP professional powerful data to analyze the effectiveness of the cathodic protection system.

The P2S-AC is the perfect tool to better understand AC corrosion issues. Use it to log data during field studies, then permanently monitor the effectiveness of your AC mitigation system.

The unit can function as a CP data logger, taking and storing measurements as often as every 15 seconds.Use it to perform field studies on variable effects on your CP system such as: changing electric transmission line loads, electric rail effects, crossing pipeline interference, and variable soil conditions. The 2 GB SDRAM card can hold several months of data, which can be transmitted to the user via the GSM/GPRS cellular link or retrieved manually.

APPLICATIONS

• AC corrosion current density measurement
• ON / OFF pipe-to-soil potentials
• Critical bond monitoring
• AC mitigation integrity
• CP field studies – electric rail, transmission line, pipeline crossing influence
• CP test point monitoring

FEATURES

• Pipe-to-soil potential (2 structures)
• IR drop-free (Instant OFF) potential
• Induced AC voltage
• AC current density (displayed in A/m2)
• DC protection current (to protected coupon)
• Bond current (bi-polar directional)
• Cellular or satellite communications
• Field replaceable Lithium battery powered – 3 to 5 year life expectancy
• Easy to use web interface
• Data logger- 2 GB SD-RAM data card
• Verify Induced AC Voltage Safety
• Simplify Compliance Reporting
• Eliminate Travel to Remote Sites
• Ensure 100 mV Polarized Potential
• No Software Required for Watchdog Web Interface

 

 

Technical Specifications
 

Part Number

GSM Cellular telemetry P2SAC-GSM
Satellite telemetry P2SAC-SAT
Operating Environment

Temperature

-40°C to + 80°C

Humidity

0 to 95%, non-condensing

Enclosure rating NEMA-4X polycarbonate

Power

Battery

Internal lithium thionyl chloride battery pack; non-rechargeable
3-5 year replacement under normal operating conditions

Installation

Mounting: Universal brackets included for pole, pipeline marker, or post mounting
Connection cable: 7' (2.1m) molded, weatherproof 7-conductor cable included w/ twist-lock
connector to unit
Satellite Unit: Separate bracket to mount 6" (15 cm) diameter satellite terminal
Electrical Connections

Inputs

Structure #1, structure #2, protected coupon, native coupon, reference cell, shunt +/-

Telemetry

GSM cellular telemetry: Quad-band (850/900/1800/1900 MHz) GSM/GPRS
Satellite telemetry: Inmarsat IsatM2M
Data Logging

Memory

2 GB SD card (4 million + readings = over 12 months of data at 8 second sample rate).

Website Controls

Remote Monitoring

Field Configuration (bond/CP test point) Reporting frequency
Alarm limits (upper & lower)

Digital Logging

Logging interval (15 sec/1min/10 min/

 

Cathodic Protection Products & Materials

  

Cathodic Protection Services

 Farwest Engineering
 Farwest Installation

  

Offshore Products Division

 Galvanic CP Systems
 Impressed CP Systems
 Attachment Systems
 Monitoring Equipment

  

Marine Products Division

 Marine ICCP Systems
 Galvanic CP Materials
 Marine Anti-Fouling
 Electrolytic De-Scaling
 Electro-Chlorination
 Marine CP Monitoring
 Galvanic Isolators

  

Corrosion Control Products Company

  

More Farwest
Website Resources

 Farwest News
 Search this Website
 Request Quote
 Order Products Online
 

Home

Products Services Search Request Quote Order Online

Farwest Corrosion Control Company
888-532-7937   (888-5FARWEST)
Complete Cathodic Protection™

Tel: 

 310-532-9524
Fax:  310-532-3934

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.farwestcorrosion.com

© 1996-2011 Farwest Corrosion Control Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956