Updates at Farwest Corrosion

Farwest Corrosion Control will be closed December 24, 25, 26, & 31, 2014 and January 1 & 2, 2015.

Image Image Image Image ImageImageImage
Anodes-Impressed Current Anodes (Galvanic/Sacrificial) CP Power Supplies Junction & Bond Boxes Test Stations & Markers Wireless Remote Monitors Anode Backfill Cable & Cable Attachment Cable Splicing & Sealing Reference Electrodes Over Voltage Fault Protection Atmospheric Protection Coatings & Tapes Isolating Products Casing Monitoring Casing Spacers, Seals & Fill Instruments & Test Equipment Surface Preparation Pipeline Repair Systems Pipeline Cleaning Pigs Rock Shields Safety Related Products Cathodic Protection Services Marine Products Division

WATCHDOG SCOUT

Web-based Remote Monitoring System with Interruption Capabilities

WATCHDOG SCOUT

Description

 The Watchdog Scout combines the installation simplicity of our VIP system with the advanced, web-based interruption capabilities of the groundbreaking Watchdog Mesh system. The Scout is designed to withstand all the challenges encountered in CP rectifier monitoring applications. The compact sized, lockable NEMA4x enclosure provides a secure, protective environment for the state of the art electronics. Advanced, self-testing circuitry automatically verifies the channel calibration to a known, stable voltage with every reading. This assures the most accurate reading available, every time! 

The Scout has been rigorously tested to withstand voltage surges up to 7500V at 3500A using conducted voltage testing per IEC 61000-4-5 specifications. This test method most closely correlates with the lightning and input power surges encountered by remote monitor equipment in the field 

The powerful Pipeline Watchdog web interface provides instant visibility to the status of your field assets, and simplifies multiple rectifier GPS-synchronized interruption, group polling, and automatic compliance report generation. 




Applications

  • CP rectifier monitoring applications 
  • Initiate/schedule group interruption cycles 
  • Digital, dry-contact status monitoring with alarming 
  • Pulse-counter/accumulator for meter-reading applications 


Features

  • Surge protection tested up to 7500V at 3500A (conducted voltage test per IEC 61000-4-5 specifications) 
  • Alarm and return to normal notifications via e-mail and/or text message 
  • 4 analog measurement channels, 2 dry-contact digital input channels (one can be used as a pulse counter/accumulator), AC mains on/off detection channel (probe included) 
  • New, “Automatic Calibration Verification” circuitry assures precision measurement accuracy every time. 
  • GPS synchronized interruption with current sensing 
  • Reconfigure units from the Watchdog user interface 
  • 2-way cellular or satellite telemetry options for reliable com-munication anywhere in the world on demand 
  • Easy to use web interface 
  • Firmware reprogrammable over the air (cellular) 
  • Modbus interface for SCADA systems 
  • AC mains on/off detection 
  • Designed for reliability in harsh, field environments 
  • Two Way Cellular or Satellite Communications 
  • Setup and Reconfigure Units From Your Computer 
  • Import Data Into Compliance Reporting Software 
  • Over the web GPS synchronized interruption capability 


Technical Specifications

 

Operating Environment 

 Temperature: -40°C to +85°C 

Humidity: 0—100% non-condensing 

Enclosure rating: NEMA 4X 

 Power 

Input Power: 8-35 Vdc or 10-25 Vac for “Always On” operation; or primary battery power 

(interruption only available using always on external power) 

Size

NEMA4x Enclosure: 8” (20.3 cm) X 10” (25.4 cm) X 4” (10.2 cm) 

I/O 

 Inputs- 4 analog measurement channels, 2 digital dry=contact channels (1 can be used as a pulse counter), 1 AC detection probe input 

Outputs– 2 relay control outputs 

Communications 

 GSM/GPRS digital cellular using TCP/IP or SMS 

Inmarsat (geo-stationary satellite network) Isat M2M Modbus (RS232) RTU slave connection for use with customer supplied SCADA data radio

Interrupter Module 

GPS synchronized 

Syncs with all popular portable interrupters 

Relay options: 100 Amp mercury relay
                           Solid state dual relay system w/mercury bypass relay 
                           Mercury-free solid state/mechanical bypass relay system 

 Measurement Accuracy 

 Rectifier voltage input:      Range = +/-200V, measurement accuracy better than +/- 100mV 

Rectifier current input:       Range = +/-100mV, measurement accuracy better than +/- 100uV 

Potential input:                    Range = +/-10V, measurement accuracy better than +/- 100uV 

Feedback
Send Us Your Feedback