Description
Amprobe’s ACD-10 PLUS multimeter offers thinner jaws than standard clamp meters, allowing access to tight measurement areas and still accommodating conductors up to 25 mm. It also measures Capacitance and Frequency. Frequency is measured by either jaws or test leads. Very versatile clamp multimeter.
Features
- AC & DC Voltage to 600V
- AC Current to 600A
- Thin Jaws only 10 mm (0.4”) thick
- Resistance to 40 MΩ
- Continuity Buzzer
- Capacitance to 3000 µF
- Frequency measurement
- Inrush current
- Hold & Maximum reading functions
- Accommodates conductors up to 26 mm (1.02”) in diameter
- Auto ranging
- Auto power off
- Rubber over-molded case
- Overload protected
- Included Accessories: Test leads, battery installed, soft carrying pouch, users manual
- Wide choice of Amprobe multimeter accessories
Specifications
DC Voltage Ranges |
400.0 mV, 4.000, 40.00, 400.0 V, 600 V |
DC Voltage Accuracy |
± 0.5% rdg ± 3 digits (± 1.0% rdg ± 4 digits on 600V scale) |
AC Voltage Ranges |
4.000, 40.00, 400.0 V, 600 V |
AC Voltage Accuracy |
± 1.5% rdg ± 5 digits (± 2.0% rdg ± 5 digit on 600V scale) |
Input Impedance |
10 MΩ |
Transient Protection |
6.5 kV (1.2 / 50 μs surge) |
AC Current (clamp-on) |
40.00, 400.0, 600 A |
Overload Protection |
600A rms continuous |
Resistance Ranges |
400.0 Ω, 4.000, 40.00, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ |
Frequency Ranges |
0 Hz to 100 kHz (depending on signal type) |
Capacitance Ranges |
500.0 nF, 5.000 μF, 50.00 μF, 500.0 μF, 3000 μF |
Diode Test |
< 1.6 VDC @ 0.25 mA |
Audible Continuity Test |
Between 10 Ω and 120 Ω |
Display |
3-3/4 digit (4000 count) LCD display |
Update Rate |
3 per second |
Polarity |
Automatic |
Operating Temperature |
0°C to 40°C |
Relative Humidity |
< 80% RH up to 31°C decreasing to 50% RH at 40°C |
Altitude |
Operation below 2000 m. Indoor use. |
Storage Temperature |
-20°C to 60°C, < 80% RH (with battery removed) |
Low Battery |
Below approx. 2.4V |
Power Supply |
3V coin battery IEC-CR2 |
Power Consumption |
2.8 mA typical, except 3.3 mA typical for ACA function |
Auto Power Off |
After being idle for 30 minutes |
Max Conductor Diameter |
26 mm (1 inch) |
Special Features |
30ms Max Hold; Data Hold; Relative Zero mode |
Dimensions |
190 x 63 x 32 mm (7.4 x 2.5 x 1.3 in) |
Weight |
139 gm |
Safety |
Meets EN61010-2-032, UL61010B-2-032, IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed. CAT III-600 Volts ac & dc; Pollution degree : 2 |
Related Products |
ACD-10 TRMS-PLUS 600A Clamp-On Multimeter |
Included Accessories
Test leads, battery installed, soft carrying pouch, users manual.