Description

The Amprobe ACD-14 PLUS multimeter is the professionals’ choice for both HVAC and Electrical applications due to its complete set of measuring features. Its dual displays allows viewing amperage and voltage simultaneously. The ACD-14 PLUS meter offers thinner jaws over standard clamp meters. Allowing access to tight measurement areas and still accommodating conductors up to 28 mm. Both meters also measure Capacitance and Frequency. Very versatile clamp multimeters to support all your daily measurement needs.



Features

  • Dual Displays – Permits simultaneous reading of Amperage & Voltage
  • AC Current to 600A
  • New thin jaws, 5 mm thinner than others to access tight measurement spaces
  • Micro Amps measurement for testing Flame Sensors
  • Capacitance to 3000 µF
  • Temperature with Type-K thermocouple probe
  • AC and DC Voltage to 600V
  • Resistance to 40 MΩ
  • Continuity Buzzer
  • Frequency measurement
  • Diode test
  • Hold and Maximum reading functions
  • Inrush current
  • Accommodates conductors up to 28 mm (1.1”) in diamete
  • Auto ranging
  • Auto power off and low battery indication
  • Rubber over-molded case
  • Wide choice of Amprobe multimeter accessories


Specifications

 

DC Voltage Ranges

400.0 mV, 4.000, 40.00, 400.0 V, 600 V

DC Voltage Accuracy

± 0.5% rdg ± 3 digits (± 1.0% rdg ± 4 digits on 600V scale)

DC µA

400.0 µA, 2000 µA

AC Voltage Ranges

4.000, 40.00, 400.0 V, 600 V (50-500 Hz)

AC Voltage Accuracy

± 1.5% rdg ± 5 digits (± 2.0% rdg ± 5 digit on 600V scale)

AC µA

400.0 µA, 2000 µA (50-500 Hz)

Input Impedance

10 MΩ

Transient Protection

6.5 kV (1.2 / 50 μs surge)

AC Current (clamp-on)

40.00, 400.0, 600 A (50-500 Hz)

AC Current Accuracy

± 1.5% rdg ± 8 digits

Overload Protection

600A rms continuous

Resistance Ranges

400.0 Ω, 4.000, 40.00, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ

Frequency Ranges

0 Hz to 100 kHz (depending on signal type)

Capacitance Ranges

50.00 nF, 500.0 nF, 5.000 μF, 50.00 μF, 500.0 μF, 3000 μF

Diode Test

< 1.6 VDC @ 0.25 mA

Audible Continuity Test

Between 10 Ω and 120 Ω

Temperature Ranges

-20°C to +537°C & -4°F to +999°F with Type K thermocouple

Display

Dual 3-3/4 digit (4000 count) LCD display

Update Rate

3 per second

Polarity

Automatic

Operating Temperature

0°C to 40°C

Relative Humidity

< 80% RH up to 31°C decreasing to 50% RH at 40°C

Altitude

Operation below 2000 m. Indoor use.

Storage Temperature

-20°C to 60°C, < 80% RH (with battery removed)

Low Battery

Below approx. 2.4V

Power Supply

Two 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2032)

Power Consumption

2.5 mA typical

Battery Life

95 hrs approx. in DCV mode.

Auto Power Off

After being idle for 30 minutes

Max Conductor Diameter

28 mm (1.1")

Dimensions

190 x 63 x 32 mm (7.5 x 2.5 x 1.3 in)

Weight

204 gm (0.45 lb)

Safety & EMC

Meets CE EN61010-1, EN61010-2-032 - Pollution Degree 2

Related Products

ACD-14 TRMS-PLUS 600A Clamp-On Multimeter

Included Accessories


 Test leads, carrying case, bead type, thermocouple with banana plug, users manual.

Optional Accessories

ELS2A

Line splitter

ACF-3000AK

3000A AC Flexible Clamp-On Attachment

TA-1A

Temperature Adapter