Cathodic Protection Rectifiers, Standard Line, Air Cooled by Universal Rectifiers

Most Popular Conventional Rectifiers. Many Available Options
  •  
    Farwest “Standard Line” air cooled cathodic protection rectifiers, manufactured by Universal Rectifiers, are recognized as industry leading in quality, workmanship and service life. Many years of field-proven service prove their superior design. Conservative equipment ratings, controlled manufacturing techniques, plus many extra features ensure long and trouble-free operation.

    Typical cathodic protection applications for the air cooled rectifier line include pipelines, storage tanks, and many other non-hazardous locations where continuous duty, DC cathodic protection power is required.

    Air cooled cathodic protection rectifier purchasing specification

     

  • Standard Rectifier Features

    • Weatherproof to NEMA 3R
    • Heavy duty 11-gauge, hot dip galvanized cabinet with stainless steel hardware
    • Stainless steel, perforated ventilation screens
    • Front and side opening doors for easy access and maintenance
    • Heavy duty, draw-pull, stainless steel cabinet latch
    • Slide-out equipment racks with separate transformer and stack assemblies for units over 1200 watts
    • Heavy-duty transformer with 15% over-design for reserve capacity
    • Standard18-step voltage control link bar taps. 
      • Additional adjustment steps can be custom ordered.
    • Quick-change, heavy-duty knobs for changing tap link bars
  • Air Cooled Rectifier Ordering Guide


    Configure a model number, like ASAI 20-20 ABCF.  Positions from left to right are as follows:

    Position #1: Model Type

    A = Standard Air Cooled Line

    Position #2: Adjustment Type

    S = Standard Rectifier (Manual taps)
    C = Constant Current (Reactor style)
    D = Constant Current (Solid state)
    E = Constant Voltage (Solid state)

    P = Constant potential (solid state)
    I = Constant potential IR free (solid state)
    M = Multiple Modes (Specify Modes Required)
    V = Variac control

    Position #3: Cooling

    A = Air Cooled

    Position #4: Stack Type

    I = Silicon (recommended)
    E = Selenium (rarely used, selenium stacks age over time)

    Position #5: DC Output Voltage Rating

    List Maximum DC Voltage Desired (such as 50 for 50 volts)

    Position #6: DC Output Amp Rating

    List Maximum DC Amperage Desired (such as 25 for 25 amps)

    Position #7: AC Input Voltage Rating

    AA = 115/230 volts, 1 phase, set for 115 VAC
    BA = 230/460 volts, 1 phase, set for 230 VAC
    CA = 230/460 volts, 3 phase, set for 230 VAC
    EA = 115/460 volts, 1 phase, set for 115 VAC
    G = 115 volts, 1 phase only
    H = 230 volts, 1 phase only

    AB = 115/230 volts, 1 phase, set for 230 VAC
    BB = 230/460 volts, 1 phase, set for 460 VAC
    CB
    = 230/460 volts, 3 phase, set for 460 VAC
    EB = 115/460 volts, 1 phase, set for 460 VAC
    D = 208 volts, 3 phase
    F = Specify requirements

    Position #8: Special Optional Features

    C = AC and DC arrestors
    D = DC arrestor
    E = AC arrestor
    F = Filter choke
    G = Communications filter
    H = Meter switches
    I  = Base mounting to standard cabinet
    J = Power "ON" indicator light
    K = DC failure warning light
    M = DC breaker (> 100 amps) or fuse
    N = Powder coated cabinet (hot-dip galvanized is standard on standard air cooled models)

    O = Aluminum cabinet option
    P = Additional voltage control link bar taps
    R = 115 VAC convenience outlet
    RR = GFCI 115 VAC outlet (Not available on all models)
    S = Multiple rectifiers in one case (Advise qty.)
    T = Anodized aluminum cabinet
    U = Anodized aluminum cabinet with clear coat
    W = RMU terminal strip
    X = Dead front safety panel
    Y = ETL Certified (Not available on all models)
    Z = Other, specify requirements

  • Air-cooled cabinets are available in the following standard size configurations.

     

      Case Dimensions (inches)
    Case
    Size 
    A B C D E F G H I J K L
    A 14.5 12 19.5 3 14.5 19 26.25 3 7.5 6 7.5 3
    B 17.5 15.5 23.5 3.5 18 23 32 3 9 8 10 6
    C 22.5 21.5 23.5 3.5 24 28 32 3 9 10 15 10
    D 28.5 22.5 23.5 3.5 25 34 32 3 9 12 21 10
    E 34 28 33 5 33 44 41.25 3 18.5 14 25 14

     

         Chassis Dimensions
    Rectifier Size Chassis Width Chassis Depth Chassis Height No. of Chassis
    A 11.5" 11.5" 18"
    B 14.5" 14.5" 10" (20" total) 2* 
    C 19" 21" 10" (20" total) 2* 
    D 25.5" 22" 10" (20" total)  2* 
  • The air cooled rectifier cabient size varies with the rectifier output size.  To determine the rectifier wattage, multiply the DC output voltage x the output current for. 

    Example:  50 volts x 50 amps = 2,500 DC watts.  Requires a size "B" rectifier cabinet.

      Single Phase  Three Phase 
    Case
    Size
    Maximum
    DC Watts
    Shipping
    Weight
    Maximum
    DC Watts
    Shipping
    Weight
    A 1,200 135 lbs - -
    B 2,800 185 lbs 1,000 255 lbs
    C 6,000 300 lbs 6,500 385 lbs
    D 10,000 400 lbs 12,000 625 lbs
    E 12,000 525 lbs 18,000 750 lbs

    Note: While this chart represents typical cabinet sizes and wattage ratings, adding optional equipment, such as a filter choke, may require that the cabinet size be increased to accept the additional equipment and/or to deal with additional heat generated by the optional equipment.