Cathodic Protection Rectifiers, Gas Station Series, Air Cooled

Low-cost CP rectifiers limited to 1,500 watts of DC output.
  • The Farwest “ProLine” air cooled cathodic protection rectifier, manufactured by Universal Rectifiers, Inc., is a low-cost rectifier option with the same
     reliability as the Standard air cooled rectifier line. Limited to 1,500 watts of DC output, this smaller rectifier is used for applications such as gas stations, pipelines, storage tanks or other non-hazardous locations where continuous duty, DC power is required.
  • Standard Rectifier Features
    • Industry leading three-year limited warranty
    • 16-gauge, NEMA 3R, powder coated cabinet with front opening door
    • Wall mounting brackets (pole mount brackets are optional)
    • Heavy-duty transformer with 15% overdesign for reserve capacity
    • Slide-out chassis
    • 20-step voltage output adjustment
    • Silicon diodes with surge suppressors
    • Hinged Bakelite front panel
    • Accessible front panel shunt
    • Magnetic AC circuit breaker
    • Hoyt model 17-3 separate volt and amp meters
    • All electrical connections are double-nutted or soldered
    • Multi-strand, high temperature insulated flexible wiring
       
    Optional Rectifier Features
    • AC and/or DC lightning protection
    • Efficiency filter chokes
    • Communication filters
    • Meter switches
    • Elapsed time meter
    • AC/DC failure light
    • DC circuit breakers or fuses
    • 115 VAC convenience outlet
    • Alternate output control (constant current, constant voltage, constant potential
    • ETL or CSA third party certification
    • Other options per request of customer
  • Typical Cabinet Dimensions
       

    Pro-1 Style Case

    Pro-2 Style Case

  • ProLine Rectifier Ordering Guide

    Configure a model number like GSAI 20-10 AC
    Positions from left to right are as follows:

    Position #1: Model

    G = ProLine Series

    Position #2: Type

    S = Standard Rectifier (manual taps)
    D = Constant Current (solid state)
    E = Constant Voltage (solid state)

    P = Constant Potential (solid state)
    M = Multiple modes (solid state)
    V = Variac control

    Position #3: Cooling

    A = Air Cooled

    Position #4: Stack Type

    I = Silicon

    Position #5: DC Volts

    List Maximum DC Voltage Desired. Do not exceed 1,500 watts total.

    Position #6: DC Amps

    List Maximum DC Amperage Desired. Do not exceed 1,500 watts total.

    Position #7: AC Input Voltage & Phase

    G = 115V, single-phase, 60 Hz

    Position #8: Special or Optional Features

    C = AC and DC arrestors
    D = DC arrestor
    E = AC arrestor
    F = Efficiency filter choke
    G = Communications filter

    H = Meter switches
    K = AC/DC failure warning light
    M
    = DC breaker or fuse
    R = 115 VAC convenience outlet
    Q = Other, specify