By continuing to browse this website or by clicking 'I Accept', you agree to the use of cookies. Cookies are stored on your computer or mobile device and enhance your site experience. To learn more about how we use cookies, you can click the 'Learn More' button.
The new Fluke 87V multimeter has improved measurement functions, trouble-shooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution and electro-mechanical equipment.
The New 80 Series consists on the following models:
Fluke 83V Industrial DMM
Fluke 87V True RMS Industrial DMM
Fluke 87 V/E2 Industrial Electricians Combo Kit
Fluke 87 V/AEK Advanced Electronic Combo Kit
Fluke 87V Ex Intrinsically Safe True RMS DMM
The 80 Series V operates very similar to the classic 80 series, but with more problem solving power, safety, convenience and impact protection.
The new 80 Series V are independently tested to comply with the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. They can withstand impulses in excess of 8,000V and reduce risks related to surges and spikes.
All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the new Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting.
Unique function for accurate measurement of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals.
Accurately measure the frequency (motor speed). Frequency measurement are not affected by the ASDs carrier frequency.
Measure AC current with an optional current clamp accessory.
Compare reading from the 87V with the display on the ASD.
Special shielding blocks high frequency, high-energy noise generated by large drive systems.
Complex PWM drive signals are no problem for the Fluke 87V.
Pulse-width modulated detail of 50 Hz motor drive output voltage. 1000 V, 50 µs can cause erratic behavior in some test equipment.
Fluke 80 Series V Digital Multimeter Selection
True-rms ac voltage and current for accurate measurements on non linear signals
•
Selectable filter for accurate voltage and frequency measurements on motor drives
•
0.05 % dc accuracy
•
6000 counts, 3-3/4 digits
•
•
4-1/2 digit mode for precise measurements (20,000 counts)
•
Measure up to 1000 V ac and dc
•
•
Measure up to 10 A, 20 A for up to 30 seconds
•
•
Built in thermometer lets you carry one less tool (TC probe included)
•
Frequency to 200 kHz and % duty cycle
•
•
Resistance, continuity and diode test
•
•
10,000 µF capacitance range for components and motor caps
•
•
Min/Max-Average recording with Min/Max Alert to capture variations automatically
•
•
Peak capture to record transients as fast as 250 µs
•
•
Relative mode to remove test lead interference from low ohms measurements
•
•
Auto and manual ranging for maximum flexibility
•
•
Touch Hold to capture stable readings avoiding noisy signals
•
•
Large display digits and two-level bright white backlight for increased visibility
•
•
Analog bargraph for fast changing or unstable signals
•
•
Input Alert provides audible warning against wrong use of input jacks
•
•
Improved selectable sleep mode for long battery life
•
•
Access door for fast battery changes without breaking the calibration seal
•
•
"Classic" design with new removable holster with built in test lead and probe storage