Description
The IsoGuard™ sealing/isolating gasket system is designed for general applications where electrical flange isolation and corrosion control are required on pipes containing water/wastewater, gas, natural gas, oil and other hydrocarbon based medias up to 302ºF(150ºC). Available for flat face, raised face and ring type joint flanges from 1/2" to 48", ANSI 150-1500# and API 2-5K, the IsoGuard™ gasket is an engineered value added solution for trouble free operation. The IsoGuard™ sealing/isolating gasket system consists of a retainer with an incline-plane seal groove geometry designed to optimize each seal's elastic memory, in conjunction with a proven rectangular sealing element ("Quad" ring). This design guarantees low bolt load requirements and high sealing reliability. IsoGuard™ systems are available with a variety of retainers and seal elements.
A Fresh Look at Sealing - Design Feature: A non-spliced (one-piece) Teflon seal element, available from 1/2" to 24". Combining this seal with the incline-plane groove design is a first for this generation of gasket technology; an excellent choice for engineers and end users wanting increased seal integrity. |
|
|
Features
Based in industry proven design.
Enhanced with innovative engineered features.
Lamons cycled tested at 10,000 psi at ambient temperature.
100% made in the USA.
Tested to Shell Certification Standards.
Features
ASTM |
TEST METHOD |
G10 |
G11 |
Phenolic |
---|---|---|---|---|
D149 |
Dielectric Strength Volts/Mil Short Time |
750-800 |
550 |
500 |
D695 |
Compressive Strength (psi) |
65,000 |
63,000 |
25,000 |
D570 |
Water Absorption (%) |
0.05 |
0.10 |
1.60 |
D790 |
Flexural Strength (psi) |
65,000 |
60,000 |
22,500 |
D256 |
IZOD Impact Strength (Ft-lbs/Inch |
14.0 |
12.0 |
1.20 |
D638 |
Tensile Strength (psi) |
50,000 |
42,000 |
20,000 |
D732 |
Shear Strength (psi) |
21,000 |
21,000 |
10,000 |
D952 |
Bond Strength (lb) |
2,600 |
2,200 |
1,500 |
|
Temperature - Operating |
Cryogenic -238°F (-150°C) to +302°F (+150°C) |
-100°F (-73°C) to +392°F (+200°C) |
+65°F (-54°C) to +220°F (+104°C) |
NOTE: Operating Temperature for Gaskets and Flange Isolation Kits is based off the Gasket Retainer Temperature. Seal element temperature does not dictate the min. and max. gasket operating temperature.
Sealing Element |
Temperature - Operating |
---|---|
Teflon® |
Cryogenic to +525°F (+274°C) |
Nitrile |
-40°F (-40°C) to +250°F (+121°C) |
Silicone |
-75°F (-115°C) to +392°F (+200°C) |
Viton® |
-20°F (-29°C) to +392°F (+200°C) |
EPDM |
-65°F (-54°C) to +250°F (+121°C) |
Type "E" Gasket |
Type "F" Gasket |
"E" or "F" Type Gaskets |
||
|
||||
Single Washer Set |
||||
Double Washer Set |
||||
|
||||
SUGGESTED SLEEVE/WASHER SETS |
||||
SD = Standard (G10 Sleeves, Steel Zp Washers and G10 Washers) - Double Washer Set |
||||
|
||||
ED = Economy (Mylar Sleeves, Steel ZP Washers and Phenolic Washers) - Double Washer Set |