Farwest distributes Lamons - ISOTEK sealing and isolation gaskets and flange kits
The Isomate™ sealing/isolating gasket is designed for basic applications where electrical flange isolation and corrosion control are required on pipes containing water/wastewater, gas, natural gas, oil and other hydrocarbon based medias up to 175ºF(79ºC).
The Isomate™ sealing/isolating gasket is designed for basic applications where electrical flange isolation and corrosion control are required on pipes containing water/wastewater, gas, natural gas, oil and other hydrocarbon based medias up to 175ºF(79ºC). Available for flat face and raised face joint flanges from 1/2" to 24", ANSI 150-300#. The Isomate gasket is an economical solution for basic performance. Isomate sealing/isolating gasket consists of a Phenolic retainer faced on both sides with Nitrile rubber material.
RETAINER MATERIALS
Phenolic
GASKET/RETAINER MATERIAL SPECIFICATIONS
ASTM
TEST METHOD
Rubber Faced Phenolic
D149
Dielectric Strength Volts/Mil Short Time
500
D695
Compressive Strength (psi)
25,000
D570
Water Absorption (%)
1.60
D790
Flexural Strength (psi)
22,500
D256
IZOD Impact Strength (Ft-lbs/Inch)
1.20
D638
Tensile Strength (psi)
20,000
D732
Shear Strength (psi)
10,000
D952
Bond Strength (lb)
1,500
Temperature - Operating
-65°F (-54°C) to +175°F (+79°C)
NOTE: Operating Temperature for Gaskets and Flange Isolation Kits is based off the Gasket Retainer Temperature. Seal element temperature does not dictate the min. and max. gasket operating temperature.
Isomate™ gaskets are engineered to provide reliable sealing and electrical isolation for a wide variety of applications.
The industry has improved sealing technology in retainer type gaskets with engineered seal elements and groove designs. Defender™ and IsoGuard™ sealing systems should be reviewed, specified and used when a long-term maintenance-free solution is necessary.
INDUSTRIES
Water/Wastewater
Oil
Gas
MEDIA
Water
Potable Water
Sea Water
Wastewater
Energy
Natural Gas
Gasoline
Crude Oil
Propane
Nitrogen
GENERAL INSTALLATION TIPS
Always use proper safety equipment.
Installation should be done with a torque wrench or stud tension measuring device.
Lamons packaged product to inspect and determine that components are as specified.
Flanges shall be free of pits, gouges, rust, debris, oil and grease. Surface finish shall be no greater than 250 RMS.
CONFIGURATIONS FOR GASKET TYPE AND SLEEVE AND WASHER SETS
Type "E" Gasket Fits over the bolt holes and extends to the O.D. of the flange to assist contractors as the bolt holes automatically center the gasket. Provides excellent protection against shorting out of the corrosion mitigation hardware.
Type "F" Gasket Fits within the bolt hole circle of the flange and extends to the I.D. of the bolt circle providing good protection against shorting out of the corrosion mitigation hardware.
"E" or "F" Type Gaskets The Isomate gasket is available in a Type "E" or "F" configuration to accommodate all your sealing/isolating needs.
Single Washer Set One isolation sleeve, one steel washer and one insulating washer for each stud/bolt.
Double Washer Set One isolation sleeve, two steel washers and two insulating washers for each stud/bolt.
SUGGESTED SLEEVE/WASHER SET
ED = Economy (Mylar Sleeves, Steel ZP Washers and Phenolic Washers) - Double Washer Set