Lida Anode "Net" by De Nora Tech

MMO Mesh Anode for Quick Installation in Structural Concrete Structures
  • Description

    • Even current distribution the highly expanded mesh pattern provides uniform cathodic protection current to the rebars.

    • Pre-fabricated the LlDA® NET Anode arrives at the job site ready to be rolled out, fastened down and connected.

    • Quick all weather installation no need to wait for curing, mixing of chemicals, cutting of slots or spraying of paints; there are no electrical splices in the concrete.
    • Activation coating mixed metal oxide coating; the LlDA® NET produces mainly oxygen.

    • Quality control LlDA® NET Anode is manufactured under strict quality control procedures, quality control certificates are provided on request .


    Typical Installations

    Material Specifications    
    Technical Data Unit

    LIDA®CN15 

    LIDA®CN25 

    LIDA®CN25 LIDA®CN35 

    Maximum rated current output
    per unit of concrete surface 

    mA/m2 

    20

    30

    40

    FHWA maximum anode current density (*)

    mA/m2

    110 110 110

    *Anode current density may be increased to 220 mA/m2. In the short term, during initial polarization, the anode current density may be increased to 400 mAm2. 

    Expected design life 

    Year 100 100 100
     Substrate Composition    

    ASTM B 265 Titanium grade 1

     
     

    Catalyst

        

    Mixed Metal Oxide for Oxygen Evolution 

     

    Nominal diamond dimensions 

     mm 85 x 38 62 x 22 40 x 19 
     

    Nominal thickness (Approx) 

     mm 1.8 1.8
     

    Lengthwise Electrical Resistance (1.2 m wide strip ) 

     

    Ohm/m 

     0.080 0.070 0.039 
          

    Widthwise Electrical Resistance 

     

    With current distributor type 1 

     

    Ohm/m 

    0.013  0.011  0.009 
     

    With current distributor type 2

     

    Ohm/m 

     0.017 0.013  0.011
          

    NET roll nominal dimensions 

     

    Width

     m 1.2  1.2  1.2 
     

    Length

     m 50  50  50 
     

    Weight per roll (Approx) 

     Kg 10  13  16 
     

    Weight/m2 of NET (Approx) 

     

    Kg/m2

     0.16 0.22  0.27 
     

    Current distributor

      

    Dimensions

      

    Electrical resistance 

     Type 1

    15 mm (width) x 1 mm (thickness) 

      
      

    0.037 Ohm/m 

    Type 2    

    10 mm (width) x 0.5 mm (thickness) 

      

    0.11 Ohm/m