Model 77 IV Digital Multimeter for Field Service by Fluke

- A Versatile Multimeter for Field Testing
-
The NEW Fluke 77-IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke's original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that's easier to view.
Features
- Wide 1000 V measurement range
- Average responding AC measurements
- 0.3% accuracy
- 10 Amps continuous (20A for 30 seconds)
- Frequency and capacitance
- Resistance and continuity
- Large display
- Backlighting for work in dim areas
- Min / Max to record signal fluctuations
- Ergonomic overmolded housing with integrated probe holders
- Optional TPAK magnetic hanger
- Auto and manual ranging
- Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards
-
Specifications
Voltage DC
Range:
6.000V - 1000V
Best Accuracy:
+/- (0.3% + 1)
Best Resolution:
0.1 mV
Voltage AC
Range:
600.0 mV-1000V
Best Accuracy:
+/- (2.0% + 2)
Best Resolution:
1.0 mV
Amps AC
Range:
60.00 mA – 10A
Best Accuracy:
+/- (1.5% + 2)
Best Resolution:
0.01mA
Amps DC
Range:
60.00 mA – 10A
Best Accuracy:
+/- (2.5% + 2)
Best Resolution:
0.01 mA
Resistance
Range:
600.0 Ω - 50 MΩ
Best Accuracy:
+/- (0.5% + 1)
Best Resolution:
0.1Ω
Capacitance
Range:
1nF- 9,999 µF
Best Accuracy:
+/- (1.2% + 2)
Best Resolution:
1 nF
Frequency
Range:
99.99Hz- 99.99kHz
Best Accuracy:
+/- (0.1% + 1)
Best Resolution:
0.01Hz
Safety
ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV
Certifications
CSA, TÜV (EN61010), UL, Π, ; (N10140),VDE
Maximum voltage
1000V between any terminal and earth ground
Surge protection
8 kV peak per IEC 61010
Ω Fuse for mA inputs
440 mA, 1000 V FAST Fuse
Ω Fuse for A inputs
11 A, 1000 V FAST Fuse
Display
Digital:
6000 counts, updates 4/sec
Bar Graph:
33 segments; Updates 32/sec
Frequency:
10,000 counts
Capacitance:
1,000 counts
Altitude
Operating:
2,000 meters
Storage:
12,000 meters
Temperature
Operating:
-10 °C to +50 °C
Storage:
-40 °C to +60 °C
Temperature Coefficient
0.1 X (specified accuracy / °C (< 18 °C or > 28 °C)
Electromagnetic Compatibility (EN 61326-1:1997)
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5 °C (9 °F)
Relative Humidity (Maximum Non-condensing)
90 % to 35 °C
75 % to 40 °C
45 % to 50 °C
Battery Life
400 hours typical (alkaline)
Size
Height:
4.3 cm
Width:
9.0 cm
Length:
18.5 cm
Weight
420 g
-
Fluke TPAK ToolPak Universal HangerThe Fluke TPAK ToolPak universal hanger attaches to the meter and can be used by itself on a nail, hook, with a piece of rope or stiff wire. Two hook-and-loop straps are used with the TPAK ToolPak universal hanger and can be wrapped around a pipe or beam. ToolPak’s magnet is used with the universal hanger and is strong enough to securely hold you meter.
Fluke i400 AC High Safety Current Clamp- Current Range: 1A to 400A
- Maximum Non-Destructive Current: 1000A
- Lowest Measurable Current: 1A
- Basic Accuracy: 2% of reading + 0.06A (45-400 Hz)
- Usable Frequency: 5 Hz to 20 kHz
- Output Level: 1 mA/A
- Maximum Conductor Size: 32 mm (1.25") diameter
- Safety: Isolated to 1000V AC rms from earth to ground. Soft non-slippery over-mold handle prevents from accidental touching live wiring
- Compatibility: Any DMM that accepts 4 mm-shrouded banana plugs and has an AC mA scale.