Model 87 V Series Multimeter by Fluke

SKU#: 04-13096
High Impedance Meter Excellent for C.P. Testing
$529.99
  • The new Fluke 87V multimeter has improved measurement functions, trouble-shooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution and electro-mechanical equipment.

    The 87 Series V operates very similar to the classic 80 series, but with more problem solving power, safety, convenience and impact protection.

    The new 87 Series V are independently tested to comply with the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. They can withstand impulses in excess of 8,000V and reduce risks related to surges and spikes.

  • Features for maximum productivity

     
    • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (87V).
         
    • Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (87V).
        
    • Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks.
        
    • Large digit display with bright, two-level backlight makes the 80- Series V significantly easier to read than older models.
  • Electrical safety

    All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.

    Correctly measure pulse-width modulated motor drive signals

    Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the new Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting.

    • Unique function for accurate measurement of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals.
    • Accurately measure the frequency (motor speed). Frequency measurement are not affected by the ASDs carrier frequency.
    • Measure AC current with an optional current clamp accessory.
    • Compare reading from the 87V with the display on the ASD.
    • Special shielding blocks high frequency, high-energy noise generated by large drive systems.
  • Fluke 80 Series V Multimeter Specifications

    Operating Specifications

    Voltage DC

    Maximum Voltage:

    1000V

    Accuracy:

    Fluke 83 V: ±(0.1%+1)

     

    Fluke 87 V: ±(0.05%+1)

    Maximum Resolution:

    Fluke 83 V: 100 µV

     

    Fluke 87 V: 10 µV

    Voltage AC

    Maximum Voltage:

    1000V

    Accuracy:

    Fluke 83 V: ±(0.5%+2)

     

    Fluke 87 V: ±(0.7%+2) True RMS

    AC Bandwidth

    Fluke 83 V: 5 kHz

     

    Fluke 87 V: 20 kHz*

     

    *with low pass filter; 3 db @ 1 kHz

    Maximum Resolution:

    0.1 mV

    Current DC

    Maximum Amps:

    10A (20 A for 30 seconds maximum)

    Amps Accuracy:

    Fluke 83 V: ±(0.4%+2)

     

    Fluke 87 V: ±(0.2%+2)

    Maximum Resolution:

    Fluke 83 V: 0.01 mA

     

    Fluke 87 V: 0.01 µA

    Current AC

    Maximum Amps:

    10A (20A for 30 seconds maximum)

    Amps Accuracy:

    Fluke 83 V: ±(1.2%+2)

     

    Fluke 87 V: ±(1.0%+2) True RMS

    Maximum Resolution:

    0.1 µA

    Resistance

    Maximum Resistance:

    50 MΩ

    Accuracy:

    Fluke 83 V: ±(0.4%+1)

     

    Fluke 87 V: ±(0.2%+1)

    Maximum Resolution:

    0.1Ω

    Capacitance

    Maximum Capacitance

    9,999 µF

    Accuracy

    ±(1%+2)

    Maximum Resolution

    0.01 nF

    Frequency

    Maximum Frequency

    200 kHz

    Accuracy

    ±(0.005%+1)

    Maximum Resolution

    0.01 Hz

    Duty Cycle

    Maximum Duty Cycle

    99.9%

    Accuracy

    ±(0.2% per khz +0.1%)

    Maximum Resolution

    0.1%

    Temperature Measurement

    Fluke 83V, 87 V/E:

    -200.0°C - 1090°C

     

    -328.0°F - 1994.0°F

     

    excluding probe

    80 BK Temperature Probe

    Range

    -40.0°C to 260°C (-40.0°F - 500°F)

    Accuracy

    2.2°C or 2%, whichever is greater

    Conductance

    Maximum Conductance

    60.00 nS

    Accuracy

    ±(1.0%+10)

    Maximum Resolution

    0.01 nS

    Diode

    Range

    3 V

    Resolution:

    1 mV

    Accuracy:

    ± (2% + 1)

    Duty Cycle Range

    Accuracy:

    Within ± (0.2% per kHz + 0.1 %)