PosiTector 6000 Coating Thickness Probes Only, by DeFelsko

SKU#: PosiTector 6000 Coating Thickness Probes Only
Probe configurations for a wide variety of materials and coating thicknesses

Grouped product items

  • Overview
    Selection Note:

    F - for ferrous metals (example: FS)
    N - for non-ferrous metals (example: PosiTector 6000 NS)
    FN - for all metal substrates (example: PosiTector 6000 FNS)

     

    Built-in Probes
     
    Built-in Probe
     
    Gage
    Models:
    F1, F2,
    F3
    N1, N2,
    N3
    FN1, FN2,
    FN3
    FT1, FT2, FT3
    Range: 0 - 60 mils 0 - 250 mils
    0 - 1500 µm 0 - 6 mm
    Accuracy*:

    + (0.05 mils + 1%)  0 - 2 mils
    + (0.1 mils + 1%) > 2 mils

    + (0.5 mils + 1%) 0-100 mils
    + (0.5 mil + 3%) > 100 mils

    + (1 um+1%)  0-50 µm
    + (2 um+1%) > 50 µm

    + (0.01 mm+1%) 0-2.5 mm
    + (0.01 mm+ 3%) > 2.5 mm

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

     
    Separate Regular Probes

     
    Regular
    Probe Models:
    FS
    NS
    FNS
    NAS
    FTS
    Range:
    0 - 60 mils 0 - 25 mils 0 - 250 mils
    0 - 1500 µm 0 - 625 mm 0 - 6 mm
    Accuracy*:

    + (0.05 mils + 1%)
    0- 2 mils
    + (0.1 mils + 1%)
    > 2 mils

    + (0.02 mils + 1%)
    0-4 mils
    + (0.1 mils + 3%)
    > 4 mils

    + (0.5 mils + 1%)
    0-100 mils
    + (0.5 mil + 3%)
    > 100 mils

    + (1 um + 1%)
    0 - 50 µm
    + (2 um + 1%)
    > 50 µm

    + (0.5 um + 1%)
    0-100 µm
     + (2 um + 3%)
    > 100 µm 

    + (0.01 mm + 1%)
    0-2.5 mm
    + (0.01 mm + 3%)
    > 2.5 mm

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

     
    90 Regular
    Probe
    Models:
    FRS
    NRS
    FNRS
    Range:
    0 - 60 mils
    0 - 1500 µm
    Accuracy*:

    + ( 0.05 mils + 1%)  0 - 2 mils
    + (0.1 mils + 1%)  > 2 mils

    + (1 µm + 1%)  0 - 50 µm
    +
    (2 µm + 1%)  > 50 µm

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

     
    Separate MicroProbes

     

    0 Microprobe

    Probe
    Models:
    F0S
    N0S
    Range:
    0 - 25 mils
    0 - 625 um
    Accuracy*:

    + (0.02 mils + 1%)  0 - 4 mils
    + (0.1 mils + 3%)  > 4 mils

    + (0.5 µm + 1%)  0 - 100 µm
    + (2 µm + 3%)  > 100 µm  

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
     
    45 Microprobe
    Probe
    Models:
    F45S
    N45S
    Range:
    0 - 25 mils
    0 - 625 µm
    Accuracy*:

    + (0.02 mils + 1%)  0 - 4 mils
    + (0.1 mils + 3%)  > 4 mils

    + (0.5 µm + 1%)  0 - 100 µm
    + (2 µm + 3%)  > 100 µm  

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

     
    90 Microprobe
    Probe
    Models:
    F90S
    N90S
    Range:
    0 - 25 mils
    0 - 625 µm
    Accuracy*:

    + (0.02 mils + 1%)  0 - 4 mils
    + (0.1 mils + 3%)  > 4 mils

    + (.5 µm + 1%)  0 - 100 µm
    + (2 µm + 3%)  > 100 µm  

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

     
    Separate High-Range Probes

     
    High-Range
    Probe
    Models:
    FNTS
    FKS
    NKS
    Range:
    0 - 250 mils 0 - 500 mils
    0 - 6 mm 0 - 13 mm
    Accuracy*:

    + (0.5 mils + 1%) 
    0 - 100 mils
    + (0.5 mil + 3%)
    > 100 mils

    + (1 mils + 3%) 
    0 - 500 mils
    + (0.02 mm + 3%)
    0 - 13 mm

    + (0.01 mm + 1%)
    0 - 2.5 mm
    + (0.01 mm + 3%)
    > 2.5 mm

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.