Description
The STELTH 7 Reference Electrode for AC Mitigation Readingscan help you answer these questions with an all-in-one solution.
The STELTH 7 for AC Mitigation Readings has all the features you love that enable our STELTH reference electrode technology to produce stable readings, plus:
Easily automate readings by connecting to a remote monitoring unit, which becomes crucial when trying to log AC potential and AC current density readings over a period of time at different times of day – as AC load can vary greatly depending on local power demands.
Uses |
AC Mitigation Readings, AC Mitigation Monitoring, AC Monitoring, AC Readings, Depolarization Potential, ON-OFF Potential, DC & AC Current Density, Native Potential, 100 mV Shift |
Size |
Varies depending on model |
Standard Lead wire
|
Any length of RHH-RHW black #16-5 tray cable wire available |
Material |
High Impact ABS, ceramic with Moisture Retention Membrane (MRM™) |
Service Life |
Minimum 30-year service life |
Shelf Life |
Infinite shelf life, infinite stability |
Certified Potential Range |
±5 millivolts vs. standard |
pH Range |
4–9 pH |
Working Temperature Range |
32° F to +176° F (0° C to 80° C) |
Material Temperature Range |
-60° F to +185° F (-51° C to 85° C) |
Models
Stelth® Model Name |
Model: Chemistry |
Use | Minimum Service Life |
Size | Standard Lead Wire |
Stelth® 7
|
SRE-024-AC20: Cu-CuSO4 SRE-027-AC20: Ag-AgCl SRE-030-AC20: Zn-ZnSO4 SRE-048-AC20: Pd-PdCl2 |
AC Mitigation Monitoring Depolarization Potential On-Off Potential DC & AC Current Density Native Potential |
30 years |
2" (51 mm) |
Any length of RHH-RHW black #16-5 tray cable wire available. |
Stelth® 7
|
SRE-031-AC200: Cu-CuSO4 SRE-032-AC200: Ag-AgCl SRE-033-AC200: Zn-ZnSO4 SRE-049-AC200: Pd-PdCl2 |
AC Mitigation Monitoring Depolarization Potential On-Off Potential DC & AC Current Density Native Potential |
30 years | 2" (51 mm) width x 21.25" (540 mm) length. |
Any length of RHH-RHW black #16-5 tray cable wire available. |
Ordering
BORIN® STELTH® 7 Solid-State Reference Electrode for AC Mitigation Readings | |
Standard Lead Wire: | 20′ of RHH-RHW black #16-5 tray cable wire (any length of wire available) |