Stelth 7 IR-Free Probe & Rocket Reference Electrodes by Borin

Take ON-Potential & IR-free OFF-Potential Readings
  • Description

    Our STELTH 7 solid-state reference electrodes are designed to:

    • Take ON-potential and IR-free OFF-potential readings of a structure without consideration for any outside influencessuch as nearby rectifiers, anode beds, electric transmission lines, trains, subways, and even steel in concrete – while reading only the single worst potential that exists on that structure (based on NACE Standard SP0177-2014).

    • Easily allow any remote monitoring and control system to automate the IR-Free ON-potential and OFF-potential readings of a structure.

    • Eliminate expensive GPS, high amperage or any interruptersfor rectifiers altogether. Instead disconnect your DC coupon to take your OFF-potential readings.

    • Take on- and off-potential readings of pipelines with sacrificial anode systems.

    • Take current density readings of the STELTH 7 coupon representing the structure in your cathodic protection system.

    • Have a minimum design life of 30 years and infinite shelf life; you can retire before your company will need to replace the reference electrodes you installed!

    • All-in-one solution with no need of external coupons in order to take your CP readings.

    • Be reliable; the STELTH 7 will maintain a stability of ±5 millivoltsover 30 years.

    • Be reused; STELTH reference electrodes can be taken in and out of service as many times as you’d like.

    • Operate in all ranges of soil and water conditions, depending on which chemistry you choose, your STELTH will thrive in any climate, including desert dry soils, flood zones, swamps, fresh water and ocean environments.


    Just a few reasons BORIN STELTH solid-state reference electrodes are unique:

    • Never need recharging or recalibrating
    • Impregnated with membrane that keeps electrolytes from drying out or getting contaminated
    • Trap hydrogen sulfide or excess chloride ions before they cause damage
    • Let you know when you have dangerous levels of AC to deal with
    • Can thrive in ALL environments, even those chemically detrimental to other reference electrodes
    • Remain accurate for their lifetime
    • Won’t die every winter


    BORIN stands behind every STELTH reference electrode you buy:

    • We test EVERY SINGLE reference electrode we make
    • You can track/trace any STELTH
    • Every STELTH is calibrated for the life of the cell
    • The STELTH reference electrodes will work for years and remain stable after you retire


    Features

    Uses

    Both STELTH 7 IR-Free Probe & STELTH 7 Rocket: measure ON-OFF Potential, Depolarization Potential, and DC Current Density, 100 mV Shift

    Size

    Varies depending on model

    Standard Lead wire
     

    20′ of RHH-RHW black #16-5 tray cable (any length of wire available)

    Material

    High Impact ABS, ceramic with Moisture Retention Membrane (MRM™)

    Service Life

    Minimum 30-year service life

    Shelf Life

    Infinite shelf life, infinite stability

    Certified Potential Range 

    ±5 millivolts vs. standard

    pH Range

    4–9 pH

    Working Temperature Range

    32° F to +176° F (0° C to 80° C)

    Material Temperature Range

    -60° F to +185° F (-51° C to 85° C)

     

  • Models

    Stelth®
    Model Name
    Model:
    Chemistry
    Use Minimum
    Service
    Life
    Size Standard
    Lead Wire

    Stelth® 7: Rocket

     

    SRE-031:
    Cu-CuSO4
    SRE-032:
    Ag-AgCl
    SRE-033:
    Zn-ZnSO4
    SRE-049:
    Pd-PdCl2
    IR-Free Probe
    100 cm2 Coupon
    On-Off Potential
    Depolarization Potential
    DC Current Density
    30 years

    2" (51 mm)
    width x 12.75"
    (324 mm) length

    Any length of
    RHH-RHW black
    #16-5 tray cable
    wire available.

     

     

    SRE-031-CSY

    STELTH® 7 Rocket – Copper-Copper Sulfate
    (Cu-CuSO4)

    Model SRE-031-CSY

    IR-Free probe with 100 cm2 coupon and Bullet Box interrupter providing ON & IR-free OFF potentials, 100mV shift, depolarization and current density readings in low chloride environments (can tolerate chloride plus bromide levels up to 1,000 ppm).

    SRE-032-SSB

    STELTH® 7 Rocket – Silver-Silver Chloride
    (Ag-AgCI)

    Model SRE-032-SSB

    IR-Free probe with 100 cm2 coupon and Bullet Box interrupter providing ON & IR-free OFF potentials, 100mV shift, depolarization and current density readings in seawater/chloride environments (with chloride plus bromide levels in excess of 1,000 ppm but less than 19,000 ppm).

     

    SRE-033-ZIR

    STELTH® 7 Rocket – Zinc-Zinc Sulfate
    (Zn-ZnSO4)
    Model SRE-033-ZSR

    IR-Free probe with 100 cm2 coupon and Bullet Box interrupter providing ON & IR-free OFF potentials, 100mV shift, depolarization and current density readings in low chloride environments (can tolerate chloride plus bromide levels up to 1,000 ppm).

  • Ordering

    STELTH® 7 IR-Free Probe & STELTH® 7 Rocket Solid-State Reference Electrodes
    Dimensions of product:  Varies depending on model
    Weight of STELTH 7: Varies depending on model
    Weight of Wire: 0.20 lbs per 10 linear feet
    Standard Lead Wire: 20′ of RHH-RHW black #16‑5 tray cable wire